Accessories

Image Part Number Description / PDF Quantity Rfq
AP033-ATTN

AP033-ATTN

Teledyne LeCroy

ATTENUATOR PLUG ON /IO

0

HVFO100-20X-TIP-U

HVFO100-20X-TIP-U

Teledyne LeCroy

OSCOPE U PROBE X20 60MHZ 5M

10

RP4000-MCX-LEAD-SI

RP4000-MCX-LEAD-SI

Teledyne LeCroy

QTY. 3 MCX 4 GHZ SOLDER-IN LEAD

0

PK007-022

PK007-022

Teledyne LeCroy

ADAPTER 2MM PLUG

3

PK-ZS-022

PK-ZS-022

Teledyne LeCroy

STRAIGHT PIN SHORT ZS4000 4/PC

1

MSO-DLS-36

MSO-DLS-36

Teledyne LeCroy

DIGITAL TEST LEAD SET

0

D350ST-SP

D350ST-SP

Teledyne LeCroy

REPLACEMENT D350ST SQUARE PIN

2

PACC-MS001

PACC-MS001

Teledyne LeCroy

REP FH PROBE HOL

11

WS10-SPMIBUS D

WS10-SPMIBUS D

Teledyne LeCroy

SPMI DECODE FOR WAVESURFER 10 SE

0

WS3K-RACK

WS3K-RACK

Teledyne LeCroy

RACK MOUNT KIT FOR WS3000

0

D500PT-TIP

D500PT-TIP

Teledyne LeCroy

REPLACEMENT D350ST SQUARE PIN

0

SAC-01

SAC-01

Teledyne LeCroy

ACCY POUCH FOR WAVERUNNER AND LC

0

PACC-ZD001

PACC-ZD001

Teledyne LeCroy

Y LEAD ADAPTER ZD DIFF PROBES

0

HDO4K-RACK

HDO4K-RACK

Teledyne LeCroy

HDO4000 RACK MOUNT ACCESSORY

0

PK4-5MM-7

PK4-5MM-7

Teledyne LeCroy

TIP INSULATOR BLACK QTY 10

0

DX10-PT-KIT

DX10-PT-KIT

Teledyne LeCroy

WAVELINK ADJUSTABLE POSITIONER

0

USB-T0P2-A01-A

USB-T0P2-A01-A

Teledyne LeCroy

ADVISOR T3 USB 2.0 PRO OPTION

1

PK1-5MM-132

PK1-5MM-132

Teledyne LeCroy

FLEXIBLE ADAPTER 5.0-L TO 4 MM

0

280 CARRYING CASE

280 CARRYING CASE

Teledyne LeCroy

QUANTUMDATA 280 DUAL CARRY CASE

0

PK1-5MM-133

PK1-5MM-133

Teledyne LeCroy

SAFETY ALLIGATOR CLIP RED

0

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments

RFQ BOM Call Skype Email