Accessories

Image Part Number Description / PDF Quantity Rfq
HDO4K-1553 TD

HDO4K-1553 TD

Teledyne LeCroy

MIL-1553 TRIGGER DECODE OPTION

0

PK-ZS-021

PK-ZS-021

Teledyne LeCroy

GND BLADE NARROW ZS4000 4/PC

1

DXX05-PT-TIPS

DXX05-PT-TIPS

Teledyne LeCroy

ADJUSTABLE POSITIONER TIP KIT

4

PK007-028

PK007-028

Teledyne LeCroy

22CM GND LEAD 2MM PLUG

3

PK-ZS-014

PK-ZS-014

Teledyne LeCroy

ADAPTER Y LEAD FOR ZS4000 4/PC

0

D11000SI

D11000SI

Teledyne LeCroy

REPLACEMENT SOLDER IN TIP

1

PK007-031

PK007-031

Teledyne LeCroy

BNC ADAPTER

22

PK-ZS-005

PK-ZS-005

Teledyne LeCroy

Y LEAD ADAPTER 4/PC

2

DX20-SI

DX20-SI

Teledyne LeCroy

SLDR TIP LEAD SET W/5 RESISTORS

0

PK106-5

PK106-5

Teledyne LeCroy

M/F LONG LEAD PP005/PPE

30

PK007-002

PK007-002

Teledyne LeCroy

11CM STANDARD GND

1

PACC-LD003

PACC-LD003

Teledyne LeCroy

RIGHT ANGLE LEAD SHORT 4/PC

2

PK1-5MM-103

PK1-5MM-103

Teledyne LeCroy

ADJUSTABLE TOOL

35

PK-ZS-024

PK-ZS-024

Teledyne LeCroy

2.54MM PCB ADAPT ZS4000 10/PC

1

PK007-016

PK007-016

Teledyne LeCroy

GROUND SPRING FOR PP008 PROBE

59

T3DSO1000-FGMOD-A

T3DSO1000-FGMOD-A

Teledyne LeCroy

MOD WAVEFORM GENERATOR 25MHZ

0

T3DSO2000A-MSO

T3DSO2000A-MSO

Teledyne LeCroy

MSO FUNCTION SOFTWARE FOR T3DSO2

0

T3SA3000-UTL

T3SA3000-UTL

Teledyne LeCroy

SPEC ANALYZER UTIL KIT W/CABLES

0

CA10

CA10

Teledyne LeCroy

PRGRMMBL CRRNT SNSR-PROBUS ADPTR

2

PACC-MS005

PACC-MS005

Teledyne LeCroy

FREEHAND PROBE HOLDER ZS

6

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments

RFQ BOM Call Skype Email
Top