Accessories

Image Part Number Description / PDF Quantity Rfq
CP015-CF01

CP015-CF01

Teledyne LeCroy

HIGH SPEED CURRENT SHUNT CP015

0

PK-HVA-01

PK-HVA-01

Teledyne LeCroy

CLIP ALLIGATOR RPLCMNT HV PROBE

0

PK-ZS-018

PK-ZS-018

Teledyne LeCroy

ADAPTER SQ PIN 2.54MM 4/PC

0

HDO4K-COVER

HDO4K-COVER

Teledyne LeCroy

PROTECTIVE COVER

0

WS4KHD-MSO-LICENSE

WS4KHD-MSO-LICENSE

Teledyne LeCroy

MSO LICENSE WSURFER 4000HD ONLY

0

WS4KHD-PWR

WS4KHD-PWR

Teledyne LeCroy

POWER ANALYSIS OPT FOR WS4000HD

0

HDO4K-MANCHESTERBUS D

HDO4K-MANCHESTERBUS D

Teledyne LeCroy

MANCHESTER BUS DECODE OPTION

0

PK1-5MM-129

PK1-5MM-129

Teledyne LeCroy

PROTECTION CAP 5.0-L

0

USB-MCDP-M03-A

USB-MCDP-M03-A

Teledyne LeCroy

SBU DECODE SFTW ADDON USB ANLZR

0

PK108

PK108

Teledyne LeCroy

PROBE ACCESSORY KIT HFP2500

0

LPA-SMA-A

LPA-SMA-A

Teledyne LeCroy

ADAPTER PRO-LINK TO SMA

0

USB-TMA2-M01-A

USB-TMA2-M01-A

Teledyne LeCroy

MERCURY T2 USB 2.0 PRO OPTION

0

PK2-5MM-102

PK2-5MM-102

Teledyne LeCroy

PROBE STD GRD LEAD

0

PK-HVA-04

PK-HVA-04

Teledyne LeCroy

CLIP ALLIGATOR RPLCMNT HV PROBE

0

LPA-K-A

LPA-K-A

Teledyne LeCroy

ADAPTER PRO-LINK TO K/2.92MM

0

PK1-5MM-125

PK1-5MM-125

Teledyne LeCroy

SOLID TIP 0.8 MM

0

WS10-MDIOBUS D

WS10-MDIOBUS D

Teledyne LeCroy

MDIO DECODE FOR WAVESURFER 10 SE

0

WS4KHD-EMB TD

WS4KHD-EMB TD

Teledyne LeCroy

I2C,SPI,UART,RS-232 TD WS4000HD

0

USB2-GPIB

USB2-GPIB

Teledyne LeCroy

USB 2.0 TO GPIB IEEE 488.2 ADAPT

0

PACC-CL001

PACC-CL001

Teledyne LeCroy

CLIP MICRO GROUND 0.5MM

0

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments

RFQ BOM Call Skype Email
Top