Accessories

Image Part Number Description / PDF Quantity Rfq
HDO4KA-L

HDO4KA-L

Teledyne LeCroy

25 MPT/CH (50 MPT INTERLEAVED) M

0

QUANTUMDATA 95-00056

QUANTUMDATA 95-00056

Teledyne LeCroy

HDMI CABLE TEST OPTION FOR 780BH

0

LPA-BNC-KIT

LPA-BNC-KIT

Teledyne LeCroy

KIT ADAPTER PROLINK BNC W/CASE

0

USB-T0P3-A01-A

USB-T0P3-A01-A

Teledyne LeCroy

ADVISOR T3 USB 3.0 PRO OPTION

0

AC031XXA-X

AC031XXA-X

Teledyne LeCroy

CABLE ASSY MICROD MICROD SYNC

0

PACC-ZD005

PACC-ZD005

Teledyne LeCroy

SWIVEL TIP ADAPTER ZD DIFF PROBE

0

PK-HV-001

PK-HV-001

Teledyne LeCroy

KIT ACCY FOR HV PROBE

0

PK600ST-4

PK600ST-4

Teledyne LeCroy

REPLACEMENT PLATFORM/CABLE ASSEM

0

DXX30-SMA-SMP

DXX30-SMA-SMP

Teledyne LeCroy

LEAD SET FOR DXX30 AMPS

0

WS4KHD-FG

WS4KHD-FG

Teledyne LeCroy

FUNC GEN FOR WAVESURFER 4000HD

0

PK111

PK111

Teledyne LeCroy

ACCY KIT - ZD500 ZD1000 ZD1500

0

DXX30-PT

DXX30-PT

Teledyne LeCroy

KIT ADJUSTABLE POSITIONER TIP

0

PACC-CD009

PACC-CD009

Teledyne LeCroy

IC GROUND BLADE

0

HDO4K-SPACEWIREBUS D

HDO4K-SPACEWIREBUS D

Teledyne LeCroy

SPCWR DCD OPT HDO4K SERIES

0

PK1-5MM-110

PK1-5MM-110

Teledyne LeCroy

BNC ADAPTER

0

PK109

PK109

Teledyne LeCroy

PROBE ACCESSORY KIT HFP1500

0

PK-HVA-02

PK-HVA-02

Teledyne LeCroy

CLIP PINCER RPLCMNT HV PROBE

0

HDO4K-RHD-02

HDO4K-RHD-02

Teledyne LeCroy

REMOVABLE HARD DRIVE

0

PK1-5MM-128

PK1-5MM-128

Teledyne LeCroy

INSULATING CAP 5.0-L

0

PK1-5MM-131

PK1-5MM-131

Teledyne LeCroy

ADJUSTMENT TOOL

0

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments

RFQ BOM Call Skype Email
Top