Accessories

Image Part Number Description / PDF Quantity Rfq
T198486

T198486

FLIR

TRIPOD ADAPTER

0

T198166

T198166

FLIR

7 LENS (F=88.9MM) WITH CASE AND

0

T199610

T199610

FLIR

BATTERY CHARGER (T5XX)

0

T911633ACC

T911633ACC

FLIR

POWER SUPPLY FOR BATTERY CHARGER

0

VSS-20

VSS-20

FLIR

20M PLUMBING SPOOL, FOR USE WITH

0

TA13

TA13

FLIR

PROTECTIVE CASE FOR TG165

0

T198126

T198126

FLIR

2 BAY BATTERY CHARGER

0

1196960

1196960

FLIR

45 LENS (45, F=10MM) WITH CASE

0

T198583

T198583

FLIR

FLIR TOOLS+ (SCRATCHCARD) 2 USER

0

T198059

T198059

FLIR

CLOSE-UP IR LENS, 2.9X (50UM) WI

0

T198065

T198065

FLIR

80 LENS (F=6.5MM) WITH CASE

0

T199589

T199589

FLIR

24 LENS WITH CASE

0

TA42

TA42

FLIR

CM 7X BELT CLIP

0

100-3201-01

100-3201-01

FLIR

*DJI MATRICE 210RTK-G (INCLUDES

0

T198509

T198509

FLIR

CIGARETTE LIGHTER ADAPTER KIT, 1

0

VSC25

VSC25

FLIR

25MM CAMERA HEAD FOR SPOOL VSS-X

0

MR10-2

MR10-2

FLIR

PROTECTIVE CASE FOR FLIR MOISTUR

1

T199588

T199588

FLIR

14 LENS WITH CASE

0

T910814

T910814

FLIR

POWER SUPPLY, INCL. MULTI PLUGS

0

MR06

MR06

FLIR

WALL CAVITY PROBE FOR FLIR MOIST

0

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments

RFQ BOM Call Skype Email
Top