Accessories

Image Part Number Description / PDF Quantity Rfq
T199559

T199559

FLIR

HIGH TEMPERATURE OPTION (+300C T

0

MR01

MR01

FLIR

REPLACEABLE TEMP/RH SENSOR FOR F

0

T197650

T197650

FLIR

2 BAY BATTERY CHARGER

0

MR-PINS2

MR-PINS2

FLIR

2 INCH PINS FOR MR06, MR07 & MR0

0

TA72

TA72

FLIR

UNIVERSAL FLEX CLAMP PROBE ACCES

0

T128390ACC

T128390ACC

FLIR

ETHERNET CABLE M12 TO RJ45

0

T911632ACC

T911632ACC

FLIR

USB TYPE-C TO HDMI ADAPTER, STA

0

TA11

TA11

FLIR

PROTECTIVE CASE FOR CM7X AND CM8

0

T911705ACC

T911705ACC

FLIR

USB TYPE-C TO USB TYPE-C CABLE (

0

T300112

T300112

FLIR

FLIR OGI LENS 6 HR (9.512 UM) WI

0

T199616

T199616

FLIR

HIGH TEMPERATURE OPTION +300C TO

0

T199557ACC

T199557ACC

FLIR

ACCESSORY BOX II EXX

0

TA03-KIT

TA03-KIT

FLIR

AAA UNIVERSAL RECHARGEABLE BATTE

0

T199362ACC

T199362ACC

FLIR

SPARE BATTERY FOR EX SERIES

1

VS-RB

VS-RB

FLIR

REPLACEMENT CENTERING BRUSH FOR

0

MR05

MR05

FLIR

IMPACT PIN MOISTURE PROBE FOR MR

0

T199363ACC

T199363ACC

FLIR

BATTERY EXX

0

T197896

T197896

FLIR

HIGH TEMPERATURE OPTION +300C TO

0

T199406ACC

T199406ACC

FLIR

BATTERY

0

MR13

MR13

FLIR

TEMPERATURE AND HUMIDITY SENSOR

1

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments

RFQ BOM Call Skype Email