Accessories

Image Part Number Description / PDF Quantity Rfq
IRW-6PS

IRW-6PS

FLIR

LARGE FORMAT IR INSPECTION WINDO

1

IRW-12PS

IRW-12PS

FLIR

LARGE FORMAT IR INSPECTION WINDO

2

IRW-3C

IRW-3C

FLIR

FLIR IRW INFRARED WINDOW 3" (O.D

1

IRW-4C

IRW-4C

FLIR

FLIR IRW INFRARED WINDOW 4" (O.D

1

IRW-12PC

IRW-12PC

FLIR

LARGE FORMAT IR INSPECTION WINDO

1

IRW-4S

IRW-4S

FLIR

FLIR IRW STAINLESS STEEL INFRARE

0

IRW-24PS

IRW-24PS

FLIR

LARGE FORMAT IR INSPECTION WINDO

2

IRW-6PC

IRW-6PC

FLIR

LARGE FORMATIR INSPECTION WINDOW

1

IRW-24PC

IRW-24PC

FLIR

LARGE FORMAT IR INSPECTION WINDO

2

T199590

T199590

FLIR

42 LENS WITH CASE

0

TA10-F

TA10-F

FLIR

PROTECTIVE CASE FOR DM9X AND TA7

0

T198066

T198066

FLIR

CLOSE-UP IR LENS, 1.5X (25UM) WI

0

T910930ACC

T910930ACC

FLIR

HDMI TYPE C TO DVI CABLE 1.5M

0

VS-BR28

VS-BR28

FLIR

CENTERING BRUSH FOR VSC28 CAMERA

0

TA15

TA15

FLIR

UNIVERSAL SOFT SIDED CASE

0

TA50

TA50

FLIR

UNIVERSAL MAGNETIC HANGING STRAP

0

T199163

T199163

FLIR

FRONT MOUNTING PLATE KIT (INCLUD

0

TA60

TA60

FLIR

UNIVERSAL THERMOCOUPLE PROBE WIT

0

T197214

T197214

FLIR

CLOSE UP LENS 2X MAGNIFICATION W

0

IRW-2C

IRW-2C

FLIR

FLIR IRW INFRARED WINDOW 2" (O.D

0

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments