Accessories

Image Part Number Description / PDF Quantity Rfq
EX010

EX010

FLIR Extech

EXT. CABLE (1M) FOR DO600 WITH P

0

FS881

FS881

FLIR Extech

FUSES, 2 PACK FOR MP, ML & MM560

0

40705X

40705X

FLIR Extech

CABLE, ANALOG OUTPUT FOR SOUND L

0

PH10-P

PH10-P

FLIR Extech

BUFFER SOLUTION/ PH 10 2 ONE PIN

0

HDV-TX2L

HDV-TX2L

FLIR Extech

6MM ARTICULATING VIDEOSCOPE LONG

0

EC-84-P

EC-84-P

FLIR Extech

CONDUCTIVITY STANDARD 2 BOTTLES

0

407764-EXT

407764-EXT

FLIR Extech

EXTENSION CABLE FOR 407764

0

PQ3210

PQ3210

FLIR Extech

1200A FLEX CLAMP (R, Y, B)

0

MO290-PINS-EP

MO290-PINS-EP

FLIR Extech

REPLACEMENT PINS/20 PAIR FOR MO2

0

LCR205

LCR205

FLIR Extech

SMD COMPONENT FIXTURE FOR LCR200

0

HDV-5CAM-1FM

HDV-5CAM-1FM

FLIR Extech

CAMERA, NARROW DEPTH OF FIELD, 5

0

SV87-KIT

SV87-KIT

FLIR Extech

GATEWAY WITH 4 REMOTE VIBRATION

3

RE305

RE305

FLIR Extech

EXSTIK ORP ELECTRODE

0

144240

144240

FLIR Extech

ADAPTER, 240VAC FOR 407780, 4077

0

EX007

EX007

FLIR Extech

24 SOLUTION CUPS W/ CAPS

0

PQ3220

PQ3220

FLIR Extech

3000A FLEX CLAMP (R, Y, B)

0

RD300-L

RD300-L

FLIR Extech

REPLACEMENT LED TIP FOR RD300

0

407510-P

407510-P

FLIR Extech

REPLACEMENT PROBE FOR 407510

0

VS290-00

VS290-00

FLIR Extech

VIDEOSCOPE DISPLAY AND BATTERY F

0

EN100-V

EN100-V

FLIR Extech

MINI IMPELLER (2 PK) FOR EN100 A

0

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments

RFQ BOM Call Skype Email
Top