Accessories

Image Part Number Description / PDF Quantity Rfq
CT70-AC

CT70-AC

FLIR Extech

AC POWER/TEST CORD FOR CT70

0

GW65

GW65

FLIR Extech

GATEWAY AND 4 AC CONNECTORS FOR

0

BR-17CAM-5M

BR-17CAM-5M

FLIR Extech

17MM BORESCOPE CAMERA HEAD WITH

0

HDV-25CAM-10G

HDV-25CAM-10G

FLIR Extech

CAMERA, PLUMBING INSPECTION, 25M

0

HDV-5CAM-30FM

HDV-5CAM-30FM

FLIR Extech

5.5MM CAMERA HEAD, 30M FLEXIBLE

0

PH7-P

PH7-P

FLIR Extech

BUFFER SOLUTION/PH 7 2 ONE PINT

0

TKG-H

TKG-H

FLIR Extech

HOLSTER FOR TKG SERIES

0

USB100

USB100

FLIR Extech

ADAPTER, RS232 TO USB

0

EX050

EX050

FLIR Extech

EXT. CABLE (5M) FOR DO600 WITH P

0

TKG-P10

TKG-P10

FLIR Extech

REPLACEMENT PROBE 10MHZ TKG SERI

0

TKG-B

TKG-B

FLIR Extech

CARRYING CASE FOR TKG SERIES

0

HDV-5CAM-10F

HDV-5CAM-10F

FLIR Extech

CAMERA, LONG DEPTH OF FIELD, 5.5

0

PWRCORD-MS420

PWRCORD-MS420

FLIR Extech

EU POWER CORD FOR MS420

0

PT150

PT150

FLIR Extech

PRESSURE TRANSDUCER, 150 PSI

0

HDV-TX1

HDV-TX1

FLIR Extech

6MM ARTICULATING VIDEOSCOPE CAME

0

HDV-25CAM-30G

HDV-25CAM-30G

FLIR Extech

CAMERA, PLUMBING INSPECTION, 25M

0

MO-P1

MO-P1

FLIR Extech

EXTERNAL MOISTURE PIN PROBE

0

MO290-PINS-HP

MO290-PINS-HP

FLIR Extech

REPLACEMENT PINS/20 PAIR FOR MO2

0

CL207

CL207

FLIR Extech

CHLORINE STANDARD (1PPM) 3 BOTTL

0

TKG-CAL

TKG-CAL

FLIR Extech

CALIBRATION BLOCK FOR TKG SERIES

0

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments