Accessories

Image Part Number Description / PDF Quantity Rfq
HDV-WTX1L

HDV-WTX1L

FLIR Extech

6MM WIRELESS ARTICULATING VIDEOS

0

BRC-17CAM

BRC-17CAM

FLIR Extech

17 MM BORESCOPE CAMERA TIP

0

PWR5

PWR5

FLIR Extech

COMPACT POWER BANK W/LED FLASHLI

0

BRD10

BRD10

FLIR Extech

USB VIDEO STREAM DONGLE

0

HDV-4CAM-5FM

HDV-4CAM-5FM

FLIR Extech

4MM CAMERA HEAD 5M FLEXIBLE CABL

0

BR-4CAM

BR-4CAM

FLIR Extech

4.5 MM BORESCOPE CAMERA TIP

0

PT150-SD

PT150-SD

FLIR Extech

150 PSI PRESSURE TRANSDUCER FOR

0

153220

153220

FLIR Extech

ADAPTER, 230V FOR 380193

0

CA-EXTECHTB

CA-EXTECHTB

FLIR Extech

EXTECH HEAVY DUTY TOOL BAG

0

1196398ACC

1196398ACC

FLIR Extech

BATTERY

0

HDV-5CAM-3F

HDV-5CAM-3F

FLIR Extech

CAMERA, LONG DEPTH OF FIELD, 5.5

0

HDV-5CAM-3R

HDV-5CAM-3R

FLIR Extech

CAMERA, LONG DEPTH OF FIELD, 5.8

0

T198487

T198487

FLIR Extech

BATTERY

0

BR-5CAM

BR-5CAM

FLIR Extech

5.5 MM BORESCOPE CAMERA TIP

0

HDV-TX1L

HDV-TX1L

FLIR Extech

6MM ARTICULATING VIDEOSCOPE LONG

0

PH155

PH155

FLIR Extech

REPLACEMENT MODULE FOR PH150-C

0

6012WS

6012WS

FLIR Extech

ELECTRODE, PH, 12MM WTRPROOF/STI

0

T198529

T198529

FLIR Extech

POUCH CASE FOR EX SERIES

0

BRC-EXT

BRC-EXT

FLIR Extech

EXTENSION CABLE FOR BR50/BR80

0

BR-9CAM-2M

BR-9CAM-2M

FLIR Extech

9MM BORESCOPE CAMERA HEAD WITH C

0

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments

RFQ BOM Call Skype Email
Top