Accessories

Image Part Number Description / PDF Quantity Rfq
SDS-5000X-4BW10

SDS-5000X-4BW10

Siglent Technologies

BANDWIDTH UPGRADE, 500 TO 1 GHZ,

4

IRW-12PS

IRW-12PS

FLIR

LARGE FORMAT IR INSPECTION WINDO

2

PS-3

PS-3

DGH Corporation

POWER SUPPLY, +24VDC, 110-220VAC

10

SPL-2016

SPL-2016

Siglent Technologies

LOGIC PROBE (MSO OPTION SDS2000X

0

PCL03V100

PCL03V100

Bartovation

RESTAURANT CHLORINE SANITIZER PL

100

03S159-K20S3

03S159-K20S3

Rosenberger

PRECISION 3.5 CALIBRATION ADAPTO

0

501R

501R

Tempo Communications

RECEIVER FOR 501

0

72-122-6

72-122-6

NTE Electronics, Inc.

BLUE INSULATOR FOR 72-120/121

713

TC-15

TC-15

Paladin Tools (Greenlee Communications)

KIT V C TESTERS CLAMPS CASE

0

P5K171-K2AS3

P5K171-K2AS3

Rosenberger

N TYPE CALIBRATION ADAPTER

0

06S121-S20S3

06S121-S20S3

Rosenberger

PRECISION TNC CALIBRATION ADAPTO

0

191-212

191-212

Hakko

SENSOR,SET OF 10,LEAD FREE SOLDE

211

AI-000500-120

AI-000500-120

Mueller Electric Co.

120" GROUND CABLE BU-21CPN

105

BU-47-5

BU-47-5

Mueller Electric Co.

INSULATOR FOR PEE-WEE PVC GREEN

393367

DAT12

DAT12

FLIR Extech

BLUETOOTH DATALOGGING MODULE

5

80AK-A

80AK-A

Fluke Electronics

ADAPTER THERMOCOUPLE TYPE K

23

M1027

M1027

Comet America

B1GINPUT MOD,MS LOGGER 0-1A

20

AI-000504-60

AI-000504-60

Mueller Electric Co.

60" GROUND CABLE NO CLIPS

44

M1053

M1053

Comet America

TG INPUT MODULE FOR LOGGER MS

20

82-2BLK

82-2BLK

E-Z-Hook

CLAMP WIRE INSUL PIERCING BLK

183

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments

RFQ BOM Call Skype Email
Top