Accessories

Image Part Number Description / PDF Quantity Rfq
PK007-008

PK007-008

Teledyne LeCroy

IC CAP FOR .5MM PKG OF 10

12

DRRM3U1

DRRM3U1

B&K Precision

RACKMNT KIT FOR ONE 3U INSTRUMEN

0

BU-31-6

BU-31-6

Mueller Electric Co.

INSULATOR

227

BU-90-6

BU-90-6

Mueller Electric Co.

INSULATOR

2146

PH105

PH105

FLIR Extech

EXSTIK PH ELECTRODE

0

PK1-5MM-105

PK1-5MM-105

Teledyne LeCroy

INSULATING CAP

1

M1007

M1007

Comet America

C1 INPUT MOD,MS LOGGER 0-1A

20

02S150-C10S3

02S150-C10S3

Rosenberger

PRECISION 2.92 CALIBRATION LOAD

0

IRW-6PS

IRW-6PS

FLIR

LARGE FORMAT IR INSPECTION WINDO

1

183432-02

183432-02

NI

CABLE ASSY,TYPE SH6868-D1,2M

11

72-102

72-102

NTE Electronics, Inc.

EXTENSION CABLE REEL BLK

17

ASTM 4 - 100G

ASTM 4 - 100G

Adam Equipment

ASTM WEIGHTS

50

38SW-A

38SW-A

Amprobe

RS232 SOFTWARE/CABLE

7

VS-AVT-CABLE-08

VS-AVT-CABLE-08

Panduit Corporation

VERISAFE REPLACEMENT AVT SYSTEM

338

LCR SMD

LCR SMD

AIMtti

SURFACE MOUNT TWEEZER (4 TERMINA

0

VS-AVT-CABLE-20

VS-AVT-CABLE-20

Panduit Corporation

VERISAFE REPLACEMENT AVT SYSTEM

210

HDO4K-SOFTCASE

HDO4K-SOFTCASE

Teledyne LeCroy

CASE SOFT CARRYING FOR HDO4000

0

PSA-ANT2

PSA-ANT2

AIMtti

WIDEBAND TELESCOPIC ANTENNA SMAN

14

72-157-0

72-157-0

NTE Electronics, Inc.

BLK INSULATOR FOR 72-148/149/153

3290

A900

A900

TPI (Test Products International)

CARRYING CASE FOR TPI 440

124

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments

RFQ BOM Call Skype Email
Top