Accessories

Image Part Number Description / PDF Quantity Rfq
DXX05-PT-TIPS

DXX05-PT-TIPS

Teledyne LeCroy

ADJUSTABLE POSITIONER TIP KIT

4

322100012

322100012

Seeed

RF EXPLORER PROTECTION BOOT (YEL

0

T1000-62HD

T1000-62HD

Tesuto

BREAKOUT BOX, D-SUB 62HD

1

FLK-TI-VISOR2

FLK-TI-VISOR2

Fluke Electronics

THERMAL IMAGER VISOR

0

MA400

MA400

B&K Precision

ADAPTER 120V 60HZ AC FOR 2650A

0

BU-87-2

BU-87-2

Mueller Electric Co.

INSULATOR FOR BU-85,85C SRS RED

8435346

ASTM 3 - 200G

ASTM 3 - 200G

Adam Equipment

ASTM WEIGHTS

50

9328

9328

Fluke Electronics

CASE CARRYING 1620-X

0

9322

9322

Fluke Electronics

CASE CARRYING (1529 AND PROBES)

0

PK007-028

PK007-028

Teledyne LeCroy

22CM GND LEAD 2MM PLUG

3

M1061

M1061

Comet America

RP INPUT MODULE FOR LOGGER MS

20

PK-ZS-014

PK-ZS-014

Teledyne LeCroy

ADAPTER Y LEAD FOR ZS4000 4/PC

0

D11000SI

D11000SI

Teledyne LeCroy

REPLACEMENT SOLDER IN TIP

1

C35

C35

Fluke Electronics

CARRYING CASE 600D SOFT

12

BU-31-9

BU-31-9

Mueller Electric Co.

INSULATOR

1583

LPH4710K30

LPH4710K30

Bartovation

30 PACK PH BUFFER CALIBRATION SO

100

VS-ACK-EXT

VS-ACK-EXT

Panduit Corporation

ACCESS CONTROL EXTENSION KIT FOR

2038

FLK-LENS/WIDE2

FLK-LENS/WIDE2

Fluke Electronics

IR WIDE ANGLE LENS

0

A345

A345

TPI (Test Products International)

THERMOCOUPLE PLUG MALE K-TYPE

539

M1001

M1001

Comet America

A0 INPUT MOD,MS LOGGER 4-20MA

20

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments

RFQ BOM Call Skype Email
Top