Accessories

Image Part Number Description / PDF Quantity Rfq
82-2VLT

82-2VLT

E-Z-Hook

CLAMP WIRE INSUL PIERC VIOLET

0

PC-5

PC-5

Fluke Electronics

1 X POWER ADAPTER X USER MANUAL

0

MQ400R

MQ400R

Bartovation

RESTAURANT QUATERNARY AMMONIUM (

100

EC605

EC605

FLIR Extech

POLYMER COND. CELL FOR EC600/DO7

0

240-139

240-139

Digilent, Inc.

OPENLOGGER ACRYLIC CASE

5

LP102

LP102

Comet America

MAGNETIC HOLDER DATALOGGER "U"

20

C1600

C1600

Fluke Electronics

GEAR BOX FOR METER AND ACCESS

0

TI-VISOR

TI-VISOR

Fluke Electronics

THERMAL IMAGER VISOR

0

09S150-C10S3

09S150-C10S3

Rosenberger

PRECISION 2.40 CALIBRATION LOAD

0

900298-00

900298-00

MadgeTech

IFC200, INTERFACE FOR 101A SERIE

20

ASTM 3 - 2G

ASTM 3 - 2G

Adam Equipment

ASTM WEIGHTS

50

MP049

MP049

Comet America

MS55D LOGGER IP54 CASE

20

05K160-K20S3

05K160-K20S3

Rosenberger

PRECISION N TYPE CALIBRATION ADA

0

P5K12S-00AS3

P5K12S-00AS3

Rosenberger

N TYPE SHORT

0

TL89K1

TL89K1

B&K Precision

KELVIN CLIP TEST FIXTURE FOR BEN

11

BU-36-0

BU-36-0

Mueller Electric Co.

INSULATOR FOR BU-34,34C SRS BK

19359000

BM511

BM511

Comet America

PLASTIC CASE FOR MULTILOGGER

20

PK-ZS-021

PK-ZS-021

Teledyne LeCroy

GND BLADE NARROW ZS4000 4/PC

1

VDV999-068

VDV999-068

Klein Tools

REPLACEMENT PROBE TIP FOR PROVE-

3

BU-23-5

BU-23-5

Mueller Electric Co.

INSULATOR FOR BU-21 SERIES GREEN

67531

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments

RFQ BOM Call Skype Email