Accessories

Image Part Number Description / PDF Quantity Rfq
PK-ZS-012

PK-ZS-012

Teledyne LeCroy

2.54MM SQUARE PIN ADAPTER 10/PC

1

MDL002

MDL002

B&K Precision

MAINFRAME EXTENSION

2

240-118

240-118

Digilent, Inc.

2X16 FLYWIRES: DIGITAL DISCOVERY

9

M1026

M1026

Comet America

B0 INPUT MOD,MS LOGGER 0-20MA

20

153QK105-K20S3

153QK105-K20S3

Rosenberger

QN CALIBRATION ADAPTER

0

72-046

72-046

NTE Electronics, Inc.

4MM PANEL SOCKET RED

14

72-119-4

72-119-4

NTE Electronics, Inc.

YEL INSULATOR FOR 72-116/117/118

591

ASTM 2 - 200G

ASTM 2 - 200G

Adam Equipment

ASTM WEIGHTS

10

A404

A404

TPI (Test Products International)

SOFTWARE/RS232 CABLE FOR TPI 460

414

72-166-5

72-166-5

NTE Electronics, Inc.

GRN INSULATOR FOR 72-167/168

755

LPA10

LPA10

Siglent Technologies

ACTIVE PROBE ADAPTER, WORK WITH

1

R1404

R1404

REED Instruments

BUFFER SOLUTION, 4.01 PH

32

ASTM 3 - 100G

ASTM 3 - 100G

Adam Equipment

ASTM WEIGHTS

50

72-143-9

72-143-9

NTE Electronics, Inc.

WHT INSULATOR FOR 72-136/137

740

PR262

PR262

B&K Precision

EMC NEAR-FIELD PROBES

4

114991658

114991658

Seeed

RF EXPLORER SIGNAL GENERATOR EXP

5

1007214-3

1007214-3

TE Connectivity Measurement Specialties

AMPLIFIER&US POWER SUPPLY PLUG

1

M1024

M1024

Comet America

Q INPUT MODULE FOR DATALOGGER MS

20

2907019

2907019

Phoenix Contact

CHECKMASTER 2 TEST ADAPTER

0

M1023

M1023

Comet America

P INPUT MODULE FOR DATALOGGER MS

20

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments

RFQ BOM Call Skype Email