Accessories

Image Part Number Description / PDF Quantity Rfq
FLK-TI-BLUETOOTH

FLK-TI-BLUETOOTH

Fluke Electronics

BLUETOOTH HEADSET

0

16171

16171

Palmer Wahl Instruments, Inc.

COMPACT AIR PURGE COLLAR FOR R10

5

06K12S-000S3

06K12S-000S3

Rosenberger

PRECISION TNC SHORT

0

CT3672

CT3672

Cal Test Electronics

COVER SHELL W/PROBE TIP GROUNDS

18

72-033

72-033

NTE Electronics, Inc.

4MM SHUTTER PLUG BLACK

90

16180

16180

Palmer Wahl Instruments, Inc.

AIR OR WATER COOLING JACKET FOR

5

PK1-5MM-120

PK1-5MM-120

Teledyne LeCroy

11CM GROUND LEAD TO .8MM PLG

8

K0945

K0945

Comet America

CONNECTION ADAPTER FOR LOGGERS

20

PK007-010

PK007-010

Teledyne LeCroy

IC CAP FOR .8MM PACK OF 10

1

QC-MPO-12/24-5P

QC-MPO-12/24-5P

Fluke Networks

QUICK CLEAN MPO 12/24 FIBER 5PK

2

SDS-5000X-4BW05

SDS-5000X-4BW05

Siglent Technologies

BANDWIDTH UPGRADE, 350 TO 500 MH

4

73106-2

73106-2

Pomona Electronics

R/A MAGNET PROBE/RED 6.6MM

38

RM200A

RM200A

AIMtti

2U RACK MOUNT FOR HALF RACK INST

0

60K34R-MSON3

60K34R-MSON3

Rosenberger

7/16 CALIBRATION KIT

0

72-036

72-036

NTE Electronics, Inc.

4MM IN LINE SOCKET RED

177

72-176-6

72-176-6

NTE Electronics, Inc.

BLUE INSULATOR FOR 72-173/173PS/

796

VC30A

VC30A

Amprobe

VINYL CARRYING CASE MED METERS

0

72-119-2

72-119-2

NTE Electronics, Inc.

RED INSULATOR FOR 72-116/117/118

422

IRW-4S

IRW-4S

FLIR

FLIR IRW STAINLESS STEEL INFRARE

0

ASTM 1 - 5G

ASTM 1 - 5G

Adam Equipment

ASTM WEIGHTS

50

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments

RFQ BOM Call Skype Email
Top