Accessories

Image Part Number Description / PDF Quantity Rfq
4112853

4112853

Fluke Electronics

GOLDCAREPLAN-GROUP4-3YR

0

H-XPA

H-XPA

Amprobe

HOLSTER CLIP MAGNET & STRAP

4

A905

A905

TPI (Test Products International)

CASE CARRY FOR TPI 460

0

109990001

109990001

Seeed

RFEMWSUB1G MODULE

0

CTM-23-4

CTM-23-4

Cal Test Electronics

MED HEAVY DUTY CLIP INSULATOR VI

250

18CK010-150

18CK010-150

Rosenberger

MINI SMP CALIBRATION KIT

0

05S121-S20S3

05S121-S20S3

Rosenberger

PRECISION N TYPE CALIBRATION ADA

0

TCONN-K

TCONN-K

American Electrical, Inc.

CONN THERMOCOUPLE PROBE K TYPE

176

BU-P1508

BU-P1508

Mueller Electric Co.

HOLDER TEST LEAD WIRES .210"

19345

T1000-37

T1000-37

Tesuto

BREAKOUT BOX, D-SUB 37

1

SMD03M

SMD03M

Peak Electronic Design Ltd

SMD TWEEZER PROBES FOR LCR/ESR (

5

PK104-1

PK104-1

Teledyne LeCroy

GND LEAD 15CM

3

ZUP/NL101

ZUP/NL101

TDK-Lambda, Inc.

BLANK PANEL USE WITH ZUP SERIES

0

SCC120E

SCC120E

Fluke Electronics

CABLE CARRYING AND SOFTWARE KIT

0

CBL-DV3

CBL-DV3

TechTools

CABLE DATA REPL FOR DV3400 18CH

3

F503ME

F503ME

Siglent Technologies

N-TYPE VNA CALIBRATION KIT (SVA

3

810SC-20

810SC-20

Fluke Electronics

SENSOR CABLE 20 FT

0

CT3653-8

CT3653-8

Cal Test Electronics

TIP INSULATOR 3.5MM GRAY

168

10113000

10113000

Fluke Networks

MODULAR ADAPTER 4 WIRE

3

R9999

R9999

REED Instruments

INDUSTRIAL TOOL BAG

136

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments

RFQ BOM Call Skype Email