Current Sensors

Image Part Number Description / PDF Quantity Rfq
HLSR 40-P

HLSR 40-P

LEM USA, Inc.

SENSOR CURRENT HALL 40A AC/DC

394

HASS 200-S

HASS 200-S

LEM USA, Inc.

SENSOR CURRENT HALL 200A AC/DC

2184

CASR 6-NP

CASR 6-NP

LEM USA, Inc.

SENSOR CURRENT FLUX 6A AC/DC

0

AT 20 B10

AT 20 B10

LEM USA, Inc.

SENSOR CURRENT XFMR 20A AC

189

HO 15-NP-0000

HO 15-NP-0000

LEM USA, Inc.

SENSOR CURRENT HALL 15A AC/DC

409

HMSR 10-SMS

HMSR 10-SMS

LEM USA, Inc.

SURFACT MT, 10A SENSOR WITH HIGH

309

HO 8-NP/SP33-1000

HO 8-NP/SP33-1000

LEM USA, Inc.

SENSOR CURRENT HALL 8A AC/DC

29

HO 8-NSM-0000

HO 8-NSM-0000

LEM USA, Inc.

SENSOR CURRENT HALL 8A AC/DC

48

HAT 1000-S

HAT 1000-S

LEM USA, Inc.

SENSOR CURRENT HALL 1000A AC/DC

0

HX 05-P

HX 05-P

LEM USA, Inc.

SENSOR CURRENT HALL 5A AC/DC

715

LF 306-S

LF 306-S

LEM USA, Inc.

SENSOR CURRENT HALL 300A AC/DC

0

LA 25-NP/SP8

LA 25-NP/SP8

LEM USA, Inc.

SENSOR CURRENT HALL 2A AC/DC

0

LESR 15-NP

LESR 15-NP

LEM USA, Inc.

SENSOR CURRENT HALL 15A UNIPOLAR

224

HO 250-S

HO 250-S

LEM USA, Inc.

SENSOR CURRENT HALL 250A AC/DC

0

HO 8-NP-0000

HO 8-NP-0000

LEM USA, Inc.

SENSOR CURRENT HALL 8A AC/DC

334

HAIS 50-P

HAIS 50-P

LEM USA, Inc.

SENSOR CURRENT HALL 50A AC/DC

347

HAL 600-S

HAL 600-S

LEM USA, Inc.

SENSOR CURRENT HALL 600A AC/DC

21

APR 50 B420L

APR 50 B420L

LEM USA, Inc.

SENSOR CURRENT 10A, 25A, 50A

0

HO 100-P

HO 100-P

LEM USA, Inc.

SENSOR CURRENT HALL 100A AC/DC

0

GO 20 SME

GO 20 SME

LEM USA, Inc.

CURRENT TRANSDUCER INTEGRATED PR

556

Current Sensors

1. Overview

Current sensors are transducers that measure electric current flow in conductors and convert it into proportional electrical signals. They play critical roles in energy management, motor control, power quality monitoring, and system protection across industries. Modern applications demand high accuracy, galvanic isolation, and fast response times for optimizing efficiency in electrified systems.

2. Major Types & Functional Classification

TypeFunctional CharacteristicsApplication Examples
Shunt ResistorLow cost, inline measurement, direct current conversion via Ohm's lawPower supplies, battery management systems
Hall EffectGalvanic isolation, DC/AC measurement, moderate bandwidthAutomotive traction inverters, industrial motor drives
Current TransformerHigh-voltage isolation, AC-only operation, high accuracyGrid metering, circuit breaker protection
Rogowski CoilFlexible coreless design, fast transient response, requires integratorPulsed power systems, fault current detection
Optical Current SensorImmune to EMI, high precision, complex signal processingSmart grids, high-voltage substations

3. Structure & Components

Typical current sensors contain: 1) Sensing element (shunt resistor, Hall chip, magnetic core) 2) Signal conditioning circuitry (amplifiers, filters) 3) Isolation barrier (if applicable) 4) Output interface (analog voltage/current, digital protocols). High-performance models integrate temperature compensation and digital calibration features.

4. Key Technical Specifications

ParameterDescriptionImportance
Measurement RangeMaximum current capacity (e.g., 500A)Determines application suitability
Accuracy ClassError tolerance (e.g., 0.5%)System control reliability
BandwidthFrequency response (DC-100kHz)Dynamic performance capability
Isolation VoltageDielectric withstand rating (e.g., 3kV)Electrical safety compliance
Response TimeSignal output delay ( s-ms range)Protection system effectiveness

5. Application Fields

Key industries include: Renewable energy (solar inverters, wind turbines), Automotive (EV battery management, 48V systems), Industrial automation (CNC machines, robotics), Consumer electronics (smart meters), Aerospace (actuator monitoring). Typical equipment: Variable frequency drives, uninterruptible power supplies, charging stations.

6. Leading Manufacturers & Products

ManufacturerProduct SeriesKey Features
LEM SAHASS & LTSR SeriesOpen-loop Hall effect with ASIC processing
Allegro MicroACS758/ACS3761xGalvanically isolated Hall ICs
HoneywellCSP-VA/CSNP SeriesCurrent transformers for grid applications
TT ElectronicsPulse SeriesHigh-precision shunt resistors
ACR SystemsRogowski Coil ModelsFlexible aperture AC measurement

7. Selection Recommendations

Key considerations: 1) Required measurement range vs peak currents 2) DC/AC signal type compatibility 3) Isolation requirements 4) Environmental conditions (temperature, vibration) 5) Cost vs performance trade-offs. Example: For EV battery management, select Hall-effect sensors with 200A range, 1% accuracy, and automotive qualification.

8. Industry Trends

Emerging trends include: 1) Integration with IoT for predictive maintenance 2) Wide bandgap semiconductor-based sensors 3) Increased adoption of closed-loop Hall sensors for EV applications 4) MEMS-based miniaturized current monitoring 5) AI-enhanced signal processing for harmonic analysis. The market is projected to grow at 7.2% CAGR through 2030 driven by electrification demands.

RFQ BOM Call Skype Email
Top