Current Sensors

Image Part Number Description / PDF Quantity Rfq
HO 120-NP

HO 120-NP

LEM USA, Inc.

SENSOR CURRENT HALL 120A AC/DC

3446

HAC 800-S

HAC 800-S

LEM USA, Inc.

SENSOR CURRENT HALL 800A AC/DC

0

HO 180-P

HO 180-P

LEM USA, Inc.

SENSOR CURRENT HALL 180A AC/DC

20

CAS 15-NP

CAS 15-NP

LEM USA, Inc.

SENSOR CURRENT FLUX 15A AC/DC

319

LAH 100-P

LAH 100-P

LEM USA, Inc.

SENSOR CURRENT HALL 100A AC/DC

0

APR 400 B420L

APR 400 B420L

LEM USA, Inc.

SENSOR CURRENT 200A, 300A, 400A

0

LF 310-S

LF 310-S

LEM USA, Inc.

C/L, ASIC 300A PANEL MOUNT

75

LTS 15-NP

LTS 15-NP

LEM USA, Inc.

SENSOR CURRENT HALL 15A AC/DC

339

LF 510-S

LF 510-S

LEM USA, Inc.

C/L, ASIC 500A PANEL MOUNT

185

HAIS 150-P

HAIS 150-P

LEM USA, Inc.

SENSOR CURRENT HALL 150A AC/DC

67

RT 2000

RT 2000

LEM USA, Inc.

SENSOR CURRENT XFMR 2000A AC

7

HAC 200-S

HAC 200-S

LEM USA, Inc.

SENSOR CURRENT HALL 200A AC/DC

0

HLSR 50-SM

HLSR 50-SM

LEM USA, Inc.

SENSOR CURRENT HALL 50A AC/DC

388

HO 150-S

HO 150-S

LEM USA, Inc.

SENSOR CURRENT HALL 150A AC/DC

0

DHR 200 C420

DHR 200 C420

LEM USA, Inc.

SENSOR CURRENT HALL 200A AC/DC

42

AT 5 B420L

AT 5 B420L

LEM USA, Inc.

SENSOR CURRENT XFMR 5A AC

0

HAS 500-S

HAS 500-S

LEM USA, Inc.

SENSOR CURRENT HALL 500A AC/DC

83

APR 200 B10

APR 200 B10

LEM USA, Inc.

SENSOR CURRENT 100A, 150A, 200A

0

LKSR 6-NP

LKSR 6-NP

LEM USA, Inc.

SENSOR CURRENT HALL 6A UNIPOLAR

173

CAS 25-NP

CAS 25-NP

LEM USA, Inc.

SENSOR CURRENT FLUX 25A AC/DC

193

Current Sensors

1. Overview

Current sensors are transducers that measure electric current flow in conductors and convert it into proportional electrical signals. They play critical roles in energy management, motor control, power quality monitoring, and system protection across industries. Modern applications demand high accuracy, galvanic isolation, and fast response times for optimizing efficiency in electrified systems.

2. Major Types & Functional Classification

TypeFunctional CharacteristicsApplication Examples
Shunt ResistorLow cost, inline measurement, direct current conversion via Ohm's lawPower supplies, battery management systems
Hall EffectGalvanic isolation, DC/AC measurement, moderate bandwidthAutomotive traction inverters, industrial motor drives
Current TransformerHigh-voltage isolation, AC-only operation, high accuracyGrid metering, circuit breaker protection
Rogowski CoilFlexible coreless design, fast transient response, requires integratorPulsed power systems, fault current detection
Optical Current SensorImmune to EMI, high precision, complex signal processingSmart grids, high-voltage substations

3. Structure & Components

Typical current sensors contain: 1) Sensing element (shunt resistor, Hall chip, magnetic core) 2) Signal conditioning circuitry (amplifiers, filters) 3) Isolation barrier (if applicable) 4) Output interface (analog voltage/current, digital protocols). High-performance models integrate temperature compensation and digital calibration features.

4. Key Technical Specifications

ParameterDescriptionImportance
Measurement RangeMaximum current capacity (e.g., 500A)Determines application suitability
Accuracy ClassError tolerance (e.g., 0.5%)System control reliability
BandwidthFrequency response (DC-100kHz)Dynamic performance capability
Isolation VoltageDielectric withstand rating (e.g., 3kV)Electrical safety compliance
Response TimeSignal output delay ( s-ms range)Protection system effectiveness

5. Application Fields

Key industries include: Renewable energy (solar inverters, wind turbines), Automotive (EV battery management, 48V systems), Industrial automation (CNC machines, robotics), Consumer electronics (smart meters), Aerospace (actuator monitoring). Typical equipment: Variable frequency drives, uninterruptible power supplies, charging stations.

6. Leading Manufacturers & Products

ManufacturerProduct SeriesKey Features
LEM SAHASS & LTSR SeriesOpen-loop Hall effect with ASIC processing
Allegro MicroACS758/ACS3761xGalvanically isolated Hall ICs
HoneywellCSP-VA/CSNP SeriesCurrent transformers for grid applications
TT ElectronicsPulse SeriesHigh-precision shunt resistors
ACR SystemsRogowski Coil ModelsFlexible aperture AC measurement

7. Selection Recommendations

Key considerations: 1) Required measurement range vs peak currents 2) DC/AC signal type compatibility 3) Isolation requirements 4) Environmental conditions (temperature, vibration) 5) Cost vs performance trade-offs. Example: For EV battery management, select Hall-effect sensors with 200A range, 1% accuracy, and automotive qualification.

8. Industry Trends

Emerging trends include: 1) Integration with IoT for predictive maintenance 2) Wide bandgap semiconductor-based sensors 3) Increased adoption of closed-loop Hall sensors for EV applications 4) MEMS-based miniaturized current monitoring 5) AI-enhanced signal processing for harmonic analysis. The market is projected to grow at 7.2% CAGR through 2030 driven by electrification demands.

RFQ BOM Call Skype Email
Top