Current Sensors

Image Part Number Description / PDF Quantity Rfq
HAS 600-S

HAS 600-S

LEM USA, Inc.

SENSOR CURRENT HALL 600A AC/DC

148

LKSR 15-NP

LKSR 15-NP

LEM USA, Inc.

SENSOR CURRENT HALL 15A UNIPOLAR

215

HAS 50-S

HAS 50-S

LEM USA, Inc.

SENSOR CURRENT HALL 50A AC/DC

316

HLSR 40-P/SP33

HLSR 40-P/SP33

LEM USA, Inc.

SENSOR CURRENT HALL 40A AC/DC

8

LA 100-TP

LA 100-TP

LEM USA, Inc.

SENSOR CURRENT HALL 100A AC/DC

132

CKSR 15-NP

CKSR 15-NP

LEM USA, Inc.

SENSOR CURRENT FLUX 15A AC/DC

86

LTSR 6-NP

LTSR 6-NP

LEM USA, Inc.

SENSOR CURRENT HALL 6A AC/DC

1

HO 6-P/SP33

HO 6-P/SP33

LEM USA, Inc.

SENSOR CURRENT HALL 6A AC/DC

11

HAX 2000-S

HAX 2000-S

LEM USA, Inc.

SENSOR CURRENT HALL 2000A AC/DC

0

HLSR 32-SM

HLSR 32-SM

LEM USA, Inc.

SENSOR CURRENT HALL 32A AC/DC

277

LAH 125-P

LAH 125-P

LEM USA, Inc.

SENSOR CURRENT HALL 125A AC/DC

0

HO 150-NP

HO 150-NP

LEM USA, Inc.

SENSOR CURRENT HALL 150A AC/DC

30

AT 50 B10

AT 50 B10

LEM USA, Inc.

SENSOR CURRENT XFMR 50A AC

101

RT 500

RT 500

LEM USA, Inc.

SENSOR CURRENT XFMR 500A AC

0

DHR 500 C420

DHR 500 C420

LEM USA, Inc.

SENSOR CURRENT HALL 500A AC/DC

0

HAS 300-P

HAS 300-P

LEM USA, Inc.

SENSOR CURRENT HALL 300A AC/DC

48

HOYL 800-S-0100

HOYL 800-S-0100

LEM USA, Inc.

800A 5V OL BUS BAR MOUNT

19

HO 15-NSM-0000

HO 15-NSM-0000

LEM USA, Inc.

SENSOR CURRENT HALL 15A AC/DC

0

LA 305-S

LA 305-S

LEM USA, Inc.

SENSOR CURRENT HALL 300A AC/DC

0

HLSR 50-P/SP33

HLSR 50-P/SP33

LEM USA, Inc.

SENSOR CURRENT HALL 50A AC/DC

0

Current Sensors

1. Overview

Current sensors are transducers that measure electric current flow in conductors and convert it into proportional electrical signals. They play critical roles in energy management, motor control, power quality monitoring, and system protection across industries. Modern applications demand high accuracy, galvanic isolation, and fast response times for optimizing efficiency in electrified systems.

2. Major Types & Functional Classification

TypeFunctional CharacteristicsApplication Examples
Shunt ResistorLow cost, inline measurement, direct current conversion via Ohm's lawPower supplies, battery management systems
Hall EffectGalvanic isolation, DC/AC measurement, moderate bandwidthAutomotive traction inverters, industrial motor drives
Current TransformerHigh-voltage isolation, AC-only operation, high accuracyGrid metering, circuit breaker protection
Rogowski CoilFlexible coreless design, fast transient response, requires integratorPulsed power systems, fault current detection
Optical Current SensorImmune to EMI, high precision, complex signal processingSmart grids, high-voltage substations

3. Structure & Components

Typical current sensors contain: 1) Sensing element (shunt resistor, Hall chip, magnetic core) 2) Signal conditioning circuitry (amplifiers, filters) 3) Isolation barrier (if applicable) 4) Output interface (analog voltage/current, digital protocols). High-performance models integrate temperature compensation and digital calibration features.

4. Key Technical Specifications

ParameterDescriptionImportance
Measurement RangeMaximum current capacity (e.g., 500A)Determines application suitability
Accuracy ClassError tolerance (e.g., 0.5%)System control reliability
BandwidthFrequency response (DC-100kHz)Dynamic performance capability
Isolation VoltageDielectric withstand rating (e.g., 3kV)Electrical safety compliance
Response TimeSignal output delay ( s-ms range)Protection system effectiveness

5. Application Fields

Key industries include: Renewable energy (solar inverters, wind turbines), Automotive (EV battery management, 48V systems), Industrial automation (CNC machines, robotics), Consumer electronics (smart meters), Aerospace (actuator monitoring). Typical equipment: Variable frequency drives, uninterruptible power supplies, charging stations.

6. Leading Manufacturers & Products

ManufacturerProduct SeriesKey Features
LEM SAHASS & LTSR SeriesOpen-loop Hall effect with ASIC processing
Allegro MicroACS758/ACS3761xGalvanically isolated Hall ICs
HoneywellCSP-VA/CSNP SeriesCurrent transformers for grid applications
TT ElectronicsPulse SeriesHigh-precision shunt resistors
ACR SystemsRogowski Coil ModelsFlexible aperture AC measurement

7. Selection Recommendations

Key considerations: 1) Required measurement range vs peak currents 2) DC/AC signal type compatibility 3) Isolation requirements 4) Environmental conditions (temperature, vibration) 5) Cost vs performance trade-offs. Example: For EV battery management, select Hall-effect sensors with 200A range, 1% accuracy, and automotive qualification.

8. Industry Trends

Emerging trends include: 1) Integration with IoT for predictive maintenance 2) Wide bandgap semiconductor-based sensors 3) Increased adoption of closed-loop Hall sensors for EV applications 4) MEMS-based miniaturized current monitoring 5) AI-enhanced signal processing for harmonic analysis. The market is projected to grow at 7.2% CAGR through 2030 driven by electrification demands.

RFQ BOM Call Skype Email
Top