AC Fans

Image Part Number Description / PDF Quantity Rfq
UF12B23-BTLR

UF12B23-BTLR

Mechatronics

FAN AXIAL 120X38MM 230VAC TERM

0

UF9439CBP23H-L

UF9439CBP23H-L

Mechatronics

FAN BLWR CF 230VAC 510X150X130MM

0

UF12B12-BWLR

UF12B12-BWLR

Mechatronics

FAN AXIAL 120X38MM 115VAC WIRE

0

UF6036CBA23H-L

UF6036CBA23H-L

Mechatronics

FAN BLWR CF 230VAC 462X98X90MM

2

UF16FC23-BTHR

UF16FC23-BTHR

Mechatronics

FAN AXIAL 160X62MM 230VAC TERM

0

UF12A12-STHR

UF12A12-STHR

Mechatronics

FAN AXIAL 120X38MM 115VAC

2643

LPH80B99-BTHR

LPH80B99-BTHR

Mechatronics

FAN AXIAL 80X25.5MM 100-240VAC

369

UF25GC12-BTHNR

UF25GC12-BTHNR

Mechatronics

FAN AXIAL 254X89MM 115VAC IP55

0

LPH12A99-BTHR-2EM-EX

LPH12A99-BTHR-2EM-EX

Mechatronics

EC FAN AXIAL 120X120X38MM 100-24

0

LPT60B99-BWHR

LPT60B99-BWHR

Mechatronics

EC FAN AXIAL 60 X 60 X 25MM 100-

31

UF12A23-SWSR

UF12A23-SWSR

Mechatronics

FAN AXIAL 120X38MM 230VAC WIRE

7

UF25HC12-BTHR-CC

UF25HC12-BTHR-CC

Mechatronics

FAN AXIAL 254X107MM 115VAC TERM

0

UF15KC12-BTHR

UF15KC12-BTHR

Mechatronics

FAN AXIAL 172X150X55MM 115VAC

294

UF12A23-BWHR

UF12A23-BWHR

Mechatronics

FAN AXIAL 120X38MM 230VAC

45

UF25GC23-BWHNR

UF25GC23-BWHNR

Mechatronics

FAN AXIAL 254X89MM 230VAC IP55

0

UF25GC12-BTHR

UF25GC12-BTHR

Mechatronics

FAN AXIAL 254X89MM 115VAC

27

UF12AR10-SWHR

UF12AR10-SWHR

Mechatronics

FAN AXIAL 120X38MM 115VAC WIRE

30

UF13A12-BWHNSR

UF13A12-BWHNSR

Mechatronics

FAN 127X38MM 115V IP55 SALT FOG

0

UF15AC23-BTHR-B1

UF15AC23-BTHR-B1

Mechatronics

FAN AXIAL 172X150X38MM 230VAC TA

0

UF220APA12-H2C2F

UF220APA12-H2C2F

Mechatronics

IMPELLER 223X71MM 115VAC RING

9

AC Fans

1. Overview

AC fans (Alternating Current Fans) are thermal management devices powered by AC electricity, primarily used to dissipate heat in electronic and mechanical systems. Operating on standard voltages (100-240V AC), they ensure optimal performance by maintaining safe temperature thresholds. Their importance has grown exponentially with advancements in high-power electronics, data centers, and industrial automation, where efficient thermal regulation prevents system failures and extends component lifespans.

2. Main Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Axial FansHigh airflow, low-pressure operation, compact designComputer cooling, HVAC systems
Centrifugal FansHigh-pressure output, compact radial airflowIndustrial ovens, dust extraction systems
Tube Axial FansIntermediate pressure, direct-drive efficiencyAir conditioning units, refrigeration systems
Vane Axial FansEnhanced aerodynamic stability, adjustable bladesPower plants, large-scale ventilation

3. Structure and Components

AC fans typically consist of: - Motor: Single-phase/three-phase induction motor with capacitor start - Blade Assembly: Plastic/metal blades optimized for aerodynamic efficiency - Bearing System: Ball bearings or sleeve bearings for durability - Frame: Metal/plastic housing with mounting brackets - Control Interface: Optional speed controllers or temperature sensors

4. Key Technical Parameters

ParameterTypical RangeSignificance
Voltage100-240V ACDetermines compatibility with power systems
Current0.1-5AAffects power consumption and heat generation
RPM600-3600Directly impacts airflow and noise levels
Airflow20-500 CFMMeasures cooling capacity
Noise Level20-60 dB(A)Critical for user comfort and workplace safety
MTBF20,000-100,000 hoursIndicates operational reliability

5. Application Fields

  • IT Infrastructure: Server racks, data center cooling
  • HVAC: Commercial air conditioning systems
  • Industrial: CNC machines, welding equipment
  • Medical: MRI scanners, laboratory equipment
  • Transportation: Electric vehicle charging stations, locomotive cooling

6. Leading Manufacturers and Products

ManufacturerProduct SeriesKey Specifications
ebm-papstAC GreenTechUp to 2,000W, EC motor integration
NidecMycom AC3-phase operation, 100,000 hours MTBF
Delta ElectronicsAC Axial SeriesVariable speed control, IP55 rating
Sanyo DenkiAC San AceHigh static pressure (300Pa), RoHS compliance

7. Selection Guidelines

Key considerations include: - Voltage/frequency compatibility with local power grids - Airflow requirements vs. static pressure demands - Noise constraints for end-user environments - Operating temperature range (-40 C to +70 C typical) - Expected operational lifespan and maintenance cycles - IP rating for dust/water protection (IP54 for industrial use) - Cost vs. energy efficiency trade-offs

Application Case Study

Data Center Cooling: A 500kW server farm required cooling solutions. Implementation of 24 ebm-papst AC GreenTech axial fans with 1,200 CFM airflow each achieved ISO Class 9 cleanroom standards while reducing energy consumption by 22% compared to conventional models.

Industry Trends Analysis

Future developments include: - Increased adoption of IoT-enabled "smart" fans with predictive maintenance - Development of oil-free ceramic bearings for medical applications - Integration with liquid cooling systems in hybrid thermal management - Growth in 400Hz AC fans for aerospace electronics - Regulatory push towards IE3+ efficiency standards compliance - Use of graphene-reinforced composite blades for weight reduction

RFQ BOM Call Skype Email
Top