AC Fans

Image Part Number Description / PDF Quantity Rfq
LPT15P23-BWHR

LPT15P23-BWHR

Mechatronics

EC FAN AXIAL 172X150X51MM 230VAC

8

UF133(72)APA23-H1S2A

UF133(72)APA23-H1S2A

Mechatronics

FAN IMP MTRZD 133X72.5MM 230VAC

5

UF92AM23-BTHR-F

UF92AM23-BTHR-F

Mechatronics

FAN AXIAL 92X38MM 230VAC TERM

9

UF12A12-BWHR

UF12A12-BWHR

Mechatronics

FAN AXIAL 120X38MM 115VAC

1073

LPH12A99-BTHR-PC

LPH12A99-BTHR-PC

Mechatronics

EC FAN AXIAL 120 X 120 X 38MM W/

200

UF15KC23-BTHR

UF15KC23-BTHR

Mechatronics

FAN AXIAL 172X150X55MM 230VAC

185

UF15KC23-BTHNSR

UF15KC23-BTHNSR

Mechatronics

172X150X55MM 230V IP55 SALT FOG

18

UF22F23-BTHR

UF22F23-BTHR

Mechatronics

FAN AXIAL 223X60MM BALL 230VAC

3

UF15PC23-BTHR

UF15PC23-BTHR

Mechatronics

FAN AXIAL 172X150X51MM 230VAC

986

UF12A12/23-BWHNSR-L24

UF12A12/23-BWHNSR-L24

Mechatronics

FAN AXIAL 120X38MM 115/230VAC

8

UF25HC23-BWHR

UF25HC23-BWHR

Mechatronics

FAN AXIAL 254X107MM 230VAC WIRE

0

UF25GC12-BWHR

UF25GC12-BWHR

Mechatronics

FAN AXIAL 254X89MM 115VAC

13

UF400AAA23-H1C4A

UF400AAA23-H1C4A

Mechatronics

IMPELLER 400X162MM 230VAC

1

UF12A12-BTSR

UF12A12-BTSR

Mechatronics

FAN AXIAL 120X38MM 115VAC TERM

0

UF12A23-BTHNSR

UF12A23-BTHNSR

Mechatronics

FAN 120X38MM 230V IP55 SALT FOG

116

UF12A12-BTLNR

UF12A12-BTLNR

Mechatronics

FAN 120X38MM 115V IP55 TERM

0

UF225(85)APA12-H1C2A

UF225(85)APA12-H1C2A

Mechatronics

IMPELLER 225X85MM 115VAC

7

UF25HC12-BWHR

UF25HC12-BWHR

Mechatronics

FAN AXIAL 254X107MM 115VAC WIRE

0

UF6036CBA12H-L

UF6036CBA12H-L

Mechatronics

FAN BLWR CF 120VAC 462X98X90MM

5

UF220APA23-H2C2F

UF220APA23-H2C2F

Mechatronics

IMPELLER 223X71MM 230VAC RING

17

AC Fans

1. Overview

AC fans (Alternating Current Fans) are thermal management devices powered by AC electricity, primarily used to dissipate heat in electronic and mechanical systems. Operating on standard voltages (100-240V AC), they ensure optimal performance by maintaining safe temperature thresholds. Their importance has grown exponentially with advancements in high-power electronics, data centers, and industrial automation, where efficient thermal regulation prevents system failures and extends component lifespans.

2. Main Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Axial FansHigh airflow, low-pressure operation, compact designComputer cooling, HVAC systems
Centrifugal FansHigh-pressure output, compact radial airflowIndustrial ovens, dust extraction systems
Tube Axial FansIntermediate pressure, direct-drive efficiencyAir conditioning units, refrigeration systems
Vane Axial FansEnhanced aerodynamic stability, adjustable bladesPower plants, large-scale ventilation

3. Structure and Components

AC fans typically consist of: - Motor: Single-phase/three-phase induction motor with capacitor start - Blade Assembly: Plastic/metal blades optimized for aerodynamic efficiency - Bearing System: Ball bearings or sleeve bearings for durability - Frame: Metal/plastic housing with mounting brackets - Control Interface: Optional speed controllers or temperature sensors

4. Key Technical Parameters

ParameterTypical RangeSignificance
Voltage100-240V ACDetermines compatibility with power systems
Current0.1-5AAffects power consumption and heat generation
RPM600-3600Directly impacts airflow and noise levels
Airflow20-500 CFMMeasures cooling capacity
Noise Level20-60 dB(A)Critical for user comfort and workplace safety
MTBF20,000-100,000 hoursIndicates operational reliability

5. Application Fields

  • IT Infrastructure: Server racks, data center cooling
  • HVAC: Commercial air conditioning systems
  • Industrial: CNC machines, welding equipment
  • Medical: MRI scanners, laboratory equipment
  • Transportation: Electric vehicle charging stations, locomotive cooling

6. Leading Manufacturers and Products

ManufacturerProduct SeriesKey Specifications
ebm-papstAC GreenTechUp to 2,000W, EC motor integration
NidecMycom AC3-phase operation, 100,000 hours MTBF
Delta ElectronicsAC Axial SeriesVariable speed control, IP55 rating
Sanyo DenkiAC San AceHigh static pressure (300Pa), RoHS compliance

7. Selection Guidelines

Key considerations include: - Voltage/frequency compatibility with local power grids - Airflow requirements vs. static pressure demands - Noise constraints for end-user environments - Operating temperature range (-40 C to +70 C typical) - Expected operational lifespan and maintenance cycles - IP rating for dust/water protection (IP54 for industrial use) - Cost vs. energy efficiency trade-offs

Application Case Study

Data Center Cooling: A 500kW server farm required cooling solutions. Implementation of 24 ebm-papst AC GreenTech axial fans with 1,200 CFM airflow each achieved ISO Class 9 cleanroom standards while reducing energy consumption by 22% compared to conventional models.

Industry Trends Analysis

Future developments include: - Increased adoption of IoT-enabled "smart" fans with predictive maintenance - Development of oil-free ceramic bearings for medical applications - Integration with liquid cooling systems in hybrid thermal management - Growth in 400Hz AC fans for aerospace electronics - Regulatory push towards IE3+ efficiency standards compliance - Use of graphene-reinforced composite blades for weight reduction

RFQ BOM Call Skype Email
Top