AC Fans

Image Part Number Description / PDF Quantity Rfq
LPT200BPB12-H1D4A

LPT200BPB12-H1D4A

Mechatronics

EC FAN AXIAL 250X76MM 120VAC 2 S

17

UF12A23-SWHR

UF12A23-SWHR

Mechatronics

FAN AXIAL 120X38MM 230VAC WIRE

0

UF12A12-BWSLR

UF12A12-BWSLR

Mechatronics

FAN AXIAL 120X38MM 115VAC WIRE

0

UF25GCA23-BWHR

UF25GCA23-BWHR

Mechatronics

FAN AXIAL 254X89MM 230VAC WIRE

10

UF12A23-BWHNR-L36

UF12A23-BWHNR-L36

Mechatronics

FAN AXIAL 120X38MM 230VAC WIRE

9

UF6030CBA12H-L

UF6030CBA12H-L

Mechatronics

FAN BLWR CF 120VAC 402X98X90MM

6

UF12AM23-BTHR-F

UF12AM23-BTHR-F

Mechatronics

FAN AXIAL 120X38MM 230VAC

89

UF15AC23-BTLR

UF15AC23-BTLR

Mechatronics

FAN AXIAL 172X150X38MM 230VAC

0

UF12A12-SWLR

UF12A12-SWLR

Mechatronics

FAN AXIAL 120X38MM 115VAC WIRE

0

UF25GCB12-BTHR

UF25GCB12-BTHR

Mechatronics

FAN AXIAL 254X89MM 115VAC TERM

0

UF15PC12-BTMR

UF15PC12-BTMR

Mechatronics

FAN AXIAL 172X150X51MM 115VAC

0

LPH60B99-BWHR

LPH60B99-BWHR

Mechatronics

FAN AXIAL 60X25.50MM 100-240VAC

129

UF15KMR12-BTHR-F

UF15KMR12-BTHR-F

Mechatronics

FAN 172X150X55MM 115V HIGH TEMP

0

UF18JC12-BTHR4

UF18JC12-BTHR4

Mechatronics

FAN AXIAL 180X90MM 115VAC

193

UF25GC23-BTHR

UF25GC23-BTHR

Mechatronics

FAN AXIAL 254X89MM 230VAC

33

UF15AC12-BTHR-B1

UF15AC12-BTHR-B1

Mechatronics

FAN AXIAL 172X150X38MM 115VAC TA

7

UF25GCA12-BTHR

UF25GCA12-BTHR

Mechatronics

FAN AXIAL 254X89MM 115VAC

460

UF15KC12/23-BWHNSR-L36

UF15KC12/23-BWHNSR-L36

Mechatronics

FAN AXIAL 172X55MM 115/230VAC

1

UF92A12-BTHR-CC

UF92A12-BTHR-CC

Mechatronics

FAN AXIAL 92X38MM 115VAC TERM

14

UF15P12-BTHR-T1

UF15P12-BTHR-T1

Mechatronics

FAN AXIAL 172X51MM 115VAC TERM

0

AC Fans

1. Overview

AC fans (Alternating Current Fans) are thermal management devices powered by AC electricity, primarily used to dissipate heat in electronic and mechanical systems. Operating on standard voltages (100-240V AC), they ensure optimal performance by maintaining safe temperature thresholds. Their importance has grown exponentially with advancements in high-power electronics, data centers, and industrial automation, where efficient thermal regulation prevents system failures and extends component lifespans.

2. Main Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Axial FansHigh airflow, low-pressure operation, compact designComputer cooling, HVAC systems
Centrifugal FansHigh-pressure output, compact radial airflowIndustrial ovens, dust extraction systems
Tube Axial FansIntermediate pressure, direct-drive efficiencyAir conditioning units, refrigeration systems
Vane Axial FansEnhanced aerodynamic stability, adjustable bladesPower plants, large-scale ventilation

3. Structure and Components

AC fans typically consist of: - Motor: Single-phase/three-phase induction motor with capacitor start - Blade Assembly: Plastic/metal blades optimized for aerodynamic efficiency - Bearing System: Ball bearings or sleeve bearings for durability - Frame: Metal/plastic housing with mounting brackets - Control Interface: Optional speed controllers or temperature sensors

4. Key Technical Parameters

ParameterTypical RangeSignificance
Voltage100-240V ACDetermines compatibility with power systems
Current0.1-5AAffects power consumption and heat generation
RPM600-3600Directly impacts airflow and noise levels
Airflow20-500 CFMMeasures cooling capacity
Noise Level20-60 dB(A)Critical for user comfort and workplace safety
MTBF20,000-100,000 hoursIndicates operational reliability

5. Application Fields

  • IT Infrastructure: Server racks, data center cooling
  • HVAC: Commercial air conditioning systems
  • Industrial: CNC machines, welding equipment
  • Medical: MRI scanners, laboratory equipment
  • Transportation: Electric vehicle charging stations, locomotive cooling

6. Leading Manufacturers and Products

ManufacturerProduct SeriesKey Specifications
ebm-papstAC GreenTechUp to 2,000W, EC motor integration
NidecMycom AC3-phase operation, 100,000 hours MTBF
Delta ElectronicsAC Axial SeriesVariable speed control, IP55 rating
Sanyo DenkiAC San AceHigh static pressure (300Pa), RoHS compliance

7. Selection Guidelines

Key considerations include: - Voltage/frequency compatibility with local power grids - Airflow requirements vs. static pressure demands - Noise constraints for end-user environments - Operating temperature range (-40 C to +70 C typical) - Expected operational lifespan and maintenance cycles - IP rating for dust/water protection (IP54 for industrial use) - Cost vs. energy efficiency trade-offs

Application Case Study

Data Center Cooling: A 500kW server farm required cooling solutions. Implementation of 24 ebm-papst AC GreenTech axial fans with 1,200 CFM airflow each achieved ISO Class 9 cleanroom standards while reducing energy consumption by 22% compared to conventional models.

Industry Trends Analysis

Future developments include: - Increased adoption of IoT-enabled "smart" fans with predictive maintenance - Development of oil-free ceramic bearings for medical applications - Integration with liquid cooling systems in hybrid thermal management - Growth in 400Hz AC fans for aerospace electronics - Regulatory push towards IE3+ efficiency standards compliance - Use of graphene-reinforced composite blades for weight reduction

RFQ BOM Call Skype Email
Top