AC Fans

Image Part Number Description / PDF Quantity Rfq
UF15PE23-BWHNR

UF15PE23-BWHNR

Mechatronics

FAN AXIAL 172X51MM 230VAC WIRE

5

UF25GC12-BTHNSR

UF25GC12-BTHNSR

Mechatronics

FAN 254X80MM 115V IP55 SALT FOG

0

UF15PC12-BTLR-CC

UF15PC12-BTLR-CC

Mechatronics

FAN AXIAL 172X150X51MM 115VAC

0

UF12A12-BTSLNSR

UF12A12-BTSLNSR

Mechatronics

FAN 120X38MM 115V IP55 SALT FOG

0

UF250BMB12-H1C2A-B1

UF250BMB12-H1C2A-B1

Mechatronics

FAN AXIAL 280X80MM 115VAC TACH

22

UF12AE12-BWHR

UF12AE12-BWHR

Mechatronics

AC FAN FRAMELESS 112X38MM 120VAC

40

UF220APA12-H2C2A-B1

UF220APA12-H2C2A-B1

Mechatronics

FAN IMP 223X71MM 115VAC TACH

0

UF80A12-SWHR

UF80A12-SWHR

Mechatronics

FAN AXIAL 80X38MM 115VAC WIRE

50

LPH12A99-BWER5

LPH12A99-BWER5

Mechatronics

EC FAN AXIAL 120X120X38MM 100-24

0

UF15KC12-BWHR

UF15KC12-BWHR

Mechatronics

FAN AXIAL 172X150X55MM 115VAC

0

UF12A23-STHR

UF12A23-STHR

Mechatronics

FAN AXIAL 120X38MM 230VAC

136

UF16FC23-BWHR4

UF16FC23-BWHR4

Mechatronics

AC FAN AXIAL 160X160X62MM, 230VA

18

UF13A12-BWHR

UF13A12-BWHR

Mechatronics

FAN AXIAL 127X38MM 115VAC WIRE

0

UF12A12-BWHNR

UF12A12-BWHNR

Mechatronics

FAN 120X38MM 115V IP55 WIRE

0

UF250APA23-H1C2A

UF250APA23-H1C2A

Mechatronics

IMPELLER 251X98MM 230VAC

14

LPT12A99-BTHR

LPT12A99-BTHR

Mechatronics

EC FAN AXIAL 120X120X38MM 100-24

11

UF9446CBP12H-L

UF9446CBP12H-L

Mechatronics

FAN BLWR CF 120VAC 570X150X130MM

2

UF12A12-BTHR

UF12A12-BTHR

Mechatronics

FAN AXIAL 120X38MM 115VAC

743

UF133(91)APA12-H1S2A

UF133(91)APA12-H1S2A

Mechatronics

IMPELLER 133X91MM 115VAC

0

UF25GC23-BWHR-L24

UF25GC23-BWHR-L24

Mechatronics

FAN AXIAL 254X89MM 230VAC WIRE

0

AC Fans

1. Overview

AC fans (Alternating Current Fans) are thermal management devices powered by AC electricity, primarily used to dissipate heat in electronic and mechanical systems. Operating on standard voltages (100-240V AC), they ensure optimal performance by maintaining safe temperature thresholds. Their importance has grown exponentially with advancements in high-power electronics, data centers, and industrial automation, where efficient thermal regulation prevents system failures and extends component lifespans.

2. Main Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Axial FansHigh airflow, low-pressure operation, compact designComputer cooling, HVAC systems
Centrifugal FansHigh-pressure output, compact radial airflowIndustrial ovens, dust extraction systems
Tube Axial FansIntermediate pressure, direct-drive efficiencyAir conditioning units, refrigeration systems
Vane Axial FansEnhanced aerodynamic stability, adjustable bladesPower plants, large-scale ventilation

3. Structure and Components

AC fans typically consist of: - Motor: Single-phase/three-phase induction motor with capacitor start - Blade Assembly: Plastic/metal blades optimized for aerodynamic efficiency - Bearing System: Ball bearings or sleeve bearings for durability - Frame: Metal/plastic housing with mounting brackets - Control Interface: Optional speed controllers or temperature sensors

4. Key Technical Parameters

ParameterTypical RangeSignificance
Voltage100-240V ACDetermines compatibility with power systems
Current0.1-5AAffects power consumption and heat generation
RPM600-3600Directly impacts airflow and noise levels
Airflow20-500 CFMMeasures cooling capacity
Noise Level20-60 dB(A)Critical for user comfort and workplace safety
MTBF20,000-100,000 hoursIndicates operational reliability

5. Application Fields

  • IT Infrastructure: Server racks, data center cooling
  • HVAC: Commercial air conditioning systems
  • Industrial: CNC machines, welding equipment
  • Medical: MRI scanners, laboratory equipment
  • Transportation: Electric vehicle charging stations, locomotive cooling

6. Leading Manufacturers and Products

ManufacturerProduct SeriesKey Specifications
ebm-papstAC GreenTechUp to 2,000W, EC motor integration
NidecMycom AC3-phase operation, 100,000 hours MTBF
Delta ElectronicsAC Axial SeriesVariable speed control, IP55 rating
Sanyo DenkiAC San AceHigh static pressure (300Pa), RoHS compliance

7. Selection Guidelines

Key considerations include: - Voltage/frequency compatibility with local power grids - Airflow requirements vs. static pressure demands - Noise constraints for end-user environments - Operating temperature range (-40 C to +70 C typical) - Expected operational lifespan and maintenance cycles - IP rating for dust/water protection (IP54 for industrial use) - Cost vs. energy efficiency trade-offs

Application Case Study

Data Center Cooling: A 500kW server farm required cooling solutions. Implementation of 24 ebm-papst AC GreenTech axial fans with 1,200 CFM airflow each achieved ISO Class 9 cleanroom standards while reducing energy consumption by 22% compared to conventional models.

Industry Trends Analysis

Future developments include: - Increased adoption of IoT-enabled "smart" fans with predictive maintenance - Development of oil-free ceramic bearings for medical applications - Integration with liquid cooling systems in hybrid thermal management - Growth in 400Hz AC fans for aerospace electronics - Regulatory push towards IE3+ efficiency standards compliance - Use of graphene-reinforced composite blades for weight reduction