Terminal Blocks - Din Rail, Channel

Image Part Number Description / PDF Quantity Rfq
3033171

3033171

Phoenix Contact

CONN TERM BLK GROUND 10-26AWG

50

3212071

3212071

Phoenix Contact

CONN TERM BLK FEED THRU 2-14 AWG

1

3038448

3038448

Phoenix Contact

CONN TERM BLK DISCONN 12-28AWG

58200

3100101

3100101

Phoenix Contact

CONN TERM BLK FEED THRU 12-28AWG

0

0719100

0719100

Phoenix Contact

CONN TERM BLK FEED THRU 12-30AWG

72

3210312

3210312

Phoenix Contact

CONN TERM BLK DISCONN 16-26AWG

0

0441106

0441106

Phoenix Contact

CONN TERM BLK GROUND 12-28AWG

1

0461018

0461018

Phoenix Contact

CONN TERM BLK FEED THRU 10-26AWG

396250

3211929

3211929

Phoenix Contact

CONN TERM BLK FEED THRU 8-20 AWG

353050

3208760

3208760

Phoenix Contact

CONN TERM BLK FEED THRU 4-20 AWG

831775

3044212

3044212

Phoenix Contact

CONN TERM BLK GROUND 4-16 AWG

454800

3208199

3208199

Phoenix Contact

CONN TERM BLK FEED THRU 14-26AWG

112

3209514

3209514

Phoenix Contact

CONN TERM BLK FEED THRU 12-26AWG

4144350

3039942

3039942

Phoenix Contact

CONN TERM BLK DISCONN 12-28AWG

0

2775375

2775375

Phoenix Contact

CONN TERM BLK FEED THRU 12-30AWG

12799300

3032130

3032130

Phoenix Contact

CONN TERM BLK DISCONN 12-28AWG

0

3037384

3037384

Phoenix Contact

CONN TERM BLK FEED THRU 10-28AWG

6515900

2800486

2800486

Phoenix Contact

CONN TERM BLK DISCONN 12-24AWG

0

3033016

3033016

Phoenix Contact

CONN TERM BLK FEED THRU 12-28AWG

105

2800570

2800570

Phoenix Contact

CONN TERM BLK FEED THRU 12-24AWG

42100

Terminal Blocks - Din Rail, Channel

1. Overview

DIN Rail and Channel Terminal Blocks are modular electrical connectors used to secure and transmit electrical signals or power between wires and devices. Designed to mount on standardized DIN rails (EN 50022) or channel rails, these components enable efficient wiring organization in industrial and commercial systems. Their importance lies in simplifying complex electrical installations, enhancing maintainability, and ensuring reliable connectivity in critical infrastructure.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Screw-Type DIN Rail Terminal BlocksUses screw clamping for secure wire connections; supports high current ratingsIndustrial control panels, HVAC systems
Spring-Clamp Terminal BlocksTool-free push-in wiring for fast installation; vibration-resistantAutomation systems, railway signaling
PCB Mount Terminal BlocksDirect printed circuit board integration; compact designTelecom equipment, medical devices
Channel Rail Terminal BlocksDesigned for C-shaped channel rails; modular expandabilityPower distribution cabinets, renewable energy systems

3. Structure and Components

Typical construction includes:

  • Conductive Elements: Copper alloy or brass contacts with tin/silver plating for corrosion resistance
  • Insulation Housing: Flame-retardant thermoplastic (UL 94 V-0 rated)
  • Mounting Mechanism: Snap-in clips for DIN rail (35mm standard) or channel rail compatibility
  • Wire Connection System: Screw terminals (M3-M4), spring clamps, or cage clamps

4. Key Technical Parameters

ParameterTypical RangeImportance
Rated Current10A - 100ADetermines power transmission capacity
Rated Voltage250V - 1000VDefines electrical insulation requirements
Wire Size Compatibility0.14mm - 300mm Matches with conductor dimensions
Insulation Resistance>1000M Ensures safety and signal integrity
Operating Temperature-20 C to +70 CMaterial performance under thermal stress

5. Application Fields

  • Industrial Automation: PLC control cabinets, motor drives
  • Energy Systems: Solar inverters, wind turbine junction boxes
  • Building Infrastructure: Smart lighting control systems
  • Rail Transport: Train power distribution panels

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Phoenix ContactPT 10-1.5/HC SeriesModular design with cross-connection capability
Weidm llerOMNIMATE PCB Terminal BlocksHigh-density PCB connectivity
Schneider ElectricEasy Connect DIN Rail BlocksIP20 protection rating, color-coded wiring
TE ConnectivityDIN-A-MITE SeriesCompact size with 6kV impulse withstand

7. Selection Guidelines

Key considerations:

  • Match current/voltage ratings with system requirements
  • Choose connection type based on maintenance needs (screw for high reliability, spring for quick changes)
  • Verify wire gauge compatibility
  • Consider environmental factors (temperature, vibration, humidity)
  • Check certifications (UL, CSA, IEC 60947)

Case Study: A smart building project selected spring-clamp terminal blocks with 600V rating and IP55 housing to enable rapid maintenance while ensuring safety in electrical rooms.

8. Industry Trends

  • Miniaturization: 30% reduction in standard DIN rail block width (e.g., 6.2mm vs. 8.4mm)
  • Smart Integration: Built-in current sensors and IoT connectivity
  • Material Innovation: Halogen-free flame retardant materials
  • Standardization: Global adoption of IEC 61535 for safe low-voltage connections
RFQ BOM Call Skype Email
Top