Terminal Blocks - Din Rail, Channel

Image Part Number Description / PDF Quantity Rfq
3213604

3213604

Phoenix Contact

CONN TERM BLK FEED THRU 10-24AWG

0

3031733

3031733

Phoenix Contact

CONN TERM BLK GROUND 12-28AWG

53500

3036372

3036372

Phoenix Contact

CONN TERM BLK DISCONN 10-28AWG

5495300

3038600

3038600

Phoenix Contact

CONN TERM BLK ISOLATED 14-26 AWG

75650

3246861

3246861

Phoenix Contact

CONN TERM BLK DISCONN 10-20AWG

0

1414129

1414129

Phoenix Contact

CONN TERM BLK FEED THRU 14-30AWG

18953600

3281124

3281124

Phoenix Contact

FEED-THROUGH TERMINAL BLOCK CONN

55

0790527

0790527

Phoenix Contact

CONN TERM BLK GROUND EARTH

22

3064098

3064098

Phoenix Contact

CONN TERM BLK FEED THRU 12-26AWG

50

3248150

3248150

Phoenix Contact

MICRO FEED-THROUGH TERMINAL BLOC

1473

3002389

3002389

Phoenix Contact

MULTI-LEVEL TERMINAL BLOCK CROSS

5041500

3214262

3214262

Phoenix Contact

CONN TERM BLK FEED THRU 12-26AWG

374

3076035

3076035

Phoenix Contact

CONN TERM BLK FEED THRU 12-26AWG

200250

3046144

3046144

Phoenix Contact

CONN TERM BLK DISCONN 10-26AWG

52

3044092

3044092

Phoenix Contact

CONN TERM BLK GROUND 12-26AWG

111018100

3048548

3048548

Phoenix Contact

CONN TERM BLK FEED THRU 10-30AWG

10

3037122

3037122

Phoenix Contact

CONN TERM BLK FEED THRU 12-28AWG

512250

3044089

3044089

Phoenix Contact

CONN TERM BLK FEED THRU 12-26AWG

13999950

3046537

3046537

Phoenix Contact

CONN TERM BLK DISCONN 10-26AWG

31500

3036482

3036482

Phoenix Contact

CONN TERM BLK GROUND 8-24 AWG

99400

Terminal Blocks - Din Rail, Channel

1. Overview

DIN Rail and Channel Terminal Blocks are modular electrical connectors used to secure and transmit electrical signals or power between wires and devices. Designed to mount on standardized DIN rails (EN 50022) or channel rails, these components enable efficient wiring organization in industrial and commercial systems. Their importance lies in simplifying complex electrical installations, enhancing maintainability, and ensuring reliable connectivity in critical infrastructure.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Screw-Type DIN Rail Terminal BlocksUses screw clamping for secure wire connections; supports high current ratingsIndustrial control panels, HVAC systems
Spring-Clamp Terminal BlocksTool-free push-in wiring for fast installation; vibration-resistantAutomation systems, railway signaling
PCB Mount Terminal BlocksDirect printed circuit board integration; compact designTelecom equipment, medical devices
Channel Rail Terminal BlocksDesigned for C-shaped channel rails; modular expandabilityPower distribution cabinets, renewable energy systems

3. Structure and Components

Typical construction includes:

  • Conductive Elements: Copper alloy or brass contacts with tin/silver plating for corrosion resistance
  • Insulation Housing: Flame-retardant thermoplastic (UL 94 V-0 rated)
  • Mounting Mechanism: Snap-in clips for DIN rail (35mm standard) or channel rail compatibility
  • Wire Connection System: Screw terminals (M3-M4), spring clamps, or cage clamps

4. Key Technical Parameters

ParameterTypical RangeImportance
Rated Current10A - 100ADetermines power transmission capacity
Rated Voltage250V - 1000VDefines electrical insulation requirements
Wire Size Compatibility0.14mm - 300mm Matches with conductor dimensions
Insulation Resistance>1000M Ensures safety and signal integrity
Operating Temperature-20 C to +70 CMaterial performance under thermal stress

5. Application Fields

  • Industrial Automation: PLC control cabinets, motor drives
  • Energy Systems: Solar inverters, wind turbine junction boxes
  • Building Infrastructure: Smart lighting control systems
  • Rail Transport: Train power distribution panels

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Phoenix ContactPT 10-1.5/HC SeriesModular design with cross-connection capability
Weidm llerOMNIMATE PCB Terminal BlocksHigh-density PCB connectivity
Schneider ElectricEasy Connect DIN Rail BlocksIP20 protection rating, color-coded wiring
TE ConnectivityDIN-A-MITE SeriesCompact size with 6kV impulse withstand

7. Selection Guidelines

Key considerations:

  • Match current/voltage ratings with system requirements
  • Choose connection type based on maintenance needs (screw for high reliability, spring for quick changes)
  • Verify wire gauge compatibility
  • Consider environmental factors (temperature, vibration, humidity)
  • Check certifications (UL, CSA, IEC 60947)

Case Study: A smart building project selected spring-clamp terminal blocks with 600V rating and IP55 housing to enable rapid maintenance while ensuring safety in electrical rooms.

8. Industry Trends

  • Miniaturization: 30% reduction in standard DIN rail block width (e.g., 6.2mm vs. 8.4mm)
  • Smart Integration: Built-in current sensors and IoT connectivity
  • Material Innovation: Halogen-free flame retardant materials
  • Standardization: Global adoption of IEC 61535 for safe low-voltage connections