Terminal Blocks - Din Rail, Channel

Image Part Number Description / PDF Quantity Rfq
3208745

3208745

Phoenix Contact

CONN TERM BLK GROUND 6-20 AWG

101850

3046317

3046317

Phoenix Contact

CONN TERM BLK FEED THRU 6-20 AWG

242050

3009163

3009163

Phoenix Contact

CONN TERM BLK FEED THRU 1/0-6AWG

5

1078966

1078966

Phoenix Contact

CONN TERM BLK FEED THRU 12-26AWG

239

3058350

3058350

Phoenix Contact

CONN TERM BLK FEED THRU 2-8 AWG

5150

3074130

3074130

Phoenix Contact

CONN TERM BLK FEED THRU 2-8 AWG

31200

3031539

3031539

Phoenix Contact

CONN TERM BLK FEED THRU 12-28AWG

504000

3076714

3076714

Phoenix Contact

CONN TERM BLK DISCONNECT 8-26AWG

509850

3248037

3248037

Phoenix Contact

CONN TERM BLK GROUND 10-24AWG

0

3213960

3213960

Phoenix Contact

CONN TERM BLK DISCONN 12-26AWG

73400

3210567

3210567

Phoenix Contact

CONN TERM BLK FEED THRU 12-26AWG

60

1415018

1415018

Phoenix Contact

CONN TERM BLK FEED THRU 10-26AWG

16

3070341

3070341

Phoenix Contact

CONN TERM BLK FEED THRU 8-24 AWG

9

3211485

3211485

Phoenix Contact

CONN TERM BLK FEED THRU 8-20 AWG

1

3209605

3209605

Phoenix Contact

CONN TERM BLK FEED THRU 12-26AWG

12

3072804

3072804

Phoenix Contact

CONN TERM BLK DISCONNECT 8-26AWG

0

3044539

3044539

Phoenix Contact

CONN TERM BLK GROUND 12-26AWG

8950

3004100

3004100

Phoenix Contact

CONN TERM BLK DISCONN 10-26AWG

14349000

3045101

3045101

Phoenix Contact

CONN TERM BLK FEED THRU 10-26AWG

3116300

3070011

3070011

Phoenix Contact

CONN TERM BLK DISCONN 10-26AWG

50

Terminal Blocks - Din Rail, Channel

1. Overview

DIN Rail and Channel Terminal Blocks are modular electrical connectors used to secure and transmit electrical signals or power between wires and devices. Designed to mount on standardized DIN rails (EN 50022) or channel rails, these components enable efficient wiring organization in industrial and commercial systems. Their importance lies in simplifying complex electrical installations, enhancing maintainability, and ensuring reliable connectivity in critical infrastructure.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Screw-Type DIN Rail Terminal BlocksUses screw clamping for secure wire connections; supports high current ratingsIndustrial control panels, HVAC systems
Spring-Clamp Terminal BlocksTool-free push-in wiring for fast installation; vibration-resistantAutomation systems, railway signaling
PCB Mount Terminal BlocksDirect printed circuit board integration; compact designTelecom equipment, medical devices
Channel Rail Terminal BlocksDesigned for C-shaped channel rails; modular expandabilityPower distribution cabinets, renewable energy systems

3. Structure and Components

Typical construction includes:

  • Conductive Elements: Copper alloy or brass contacts with tin/silver plating for corrosion resistance
  • Insulation Housing: Flame-retardant thermoplastic (UL 94 V-0 rated)
  • Mounting Mechanism: Snap-in clips for DIN rail (35mm standard) or channel rail compatibility
  • Wire Connection System: Screw terminals (M3-M4), spring clamps, or cage clamps

4. Key Technical Parameters

ParameterTypical RangeImportance
Rated Current10A - 100ADetermines power transmission capacity
Rated Voltage250V - 1000VDefines electrical insulation requirements
Wire Size Compatibility0.14mm - 300mm Matches with conductor dimensions
Insulation Resistance>1000M Ensures safety and signal integrity
Operating Temperature-20 C to +70 CMaterial performance under thermal stress

5. Application Fields

  • Industrial Automation: PLC control cabinets, motor drives
  • Energy Systems: Solar inverters, wind turbine junction boxes
  • Building Infrastructure: Smart lighting control systems
  • Rail Transport: Train power distribution panels

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Phoenix ContactPT 10-1.5/HC SeriesModular design with cross-connection capability
Weidm llerOMNIMATE PCB Terminal BlocksHigh-density PCB connectivity
Schneider ElectricEasy Connect DIN Rail BlocksIP20 protection rating, color-coded wiring
TE ConnectivityDIN-A-MITE SeriesCompact size with 6kV impulse withstand

7. Selection Guidelines

Key considerations:

  • Match current/voltage ratings with system requirements
  • Choose connection type based on maintenance needs (screw for high reliability, spring for quick changes)
  • Verify wire gauge compatibility
  • Consider environmental factors (temperature, vibration, humidity)
  • Check certifications (UL, CSA, IEC 60947)

Case Study: A smart building project selected spring-clamp terminal blocks with 600V rating and IP55 housing to enable rapid maintenance while ensuring safety in electrical rooms.

8. Industry Trends

  • Miniaturization: 30% reduction in standard DIN rail block width (e.g., 6.2mm vs. 8.4mm)
  • Smart Integration: Built-in current sensors and IoT connectivity
  • Material Innovation: Halogen-free flame retardant materials
  • Standardization: Global adoption of IEC 61535 for safe low-voltage connections