Terminal Blocks - Din Rail, Channel

Image Part Number Description / PDF Quantity Rfq
2717113

2717113

Phoenix Contact

CONN TERM BLK DISCONN 14-30AWG

29

3211813

3211813

Phoenix Contact

CONN TERM BLK FEED THRU 8-20 AWG

12941400

1078971

1078971

Phoenix Contact

CONN TERM BLK FEED THRU 12-26AWG

45

3004977

3004977

Phoenix Contact

CONN TERM BLK FEED THRU 8-26 AWG

381100

3211797

3211797

Phoenix Contact

CONN TERM BLK FEED THRU 10-24AWG

2147483647

0442024

0442024

Phoenix Contact

CONN TERM BLK GROUND 8-26 AWG

10

3037371

3037371

Phoenix Contact

CONN TERM BLK FEED THRU 10-28AWG

1401950

0452027

0452027

Phoenix Contact

CONN TERM BLK GROUND 12-28AWG

250

3210308

3210308

Phoenix Contact

CONN TERM BLK FEED THRU 16-26AWG

4

3211780

3211780

Phoenix Contact

CONN TERM BLK GROUND 10-24AWG

1311150

2296870

2296870

Phoenix Contact

CONN TERM BLK FEED THRU 12-24AWG

32

3047714

3047714

Phoenix Contact

CONN TERM BLK FEED THRU 10-26AWG

180

3037423

3037423

Phoenix Contact

CONN TERM BLK FEED THRU 12-28AWG

281100

3244119

3244119

Phoenix Contact

CONN TERM BLK FEED THRU 12-28AWG

1301900

3035373

3035373

Phoenix Contact

CONN TERM BLK FEED THRU 12-28AWG

3

3210192

3210192

Phoenix Contact

CONN TERM BLK DISCONN 12-26AWG

260

5043321

5043321

Phoenix Contact

CONN TERM BLK FEED THRU 12-28AWG

2

3049424

3049424

Phoenix Contact

CONN TERM BLK GROUND 10-26AWG

41600

3210341

3210341

Phoenix Contact

CONN TERM BLK DISCONN 16-26AWG

50

0501059

0501059

Phoenix Contact

CONN TERM BLK FEED THROUGH WHITE

2631400

Terminal Blocks - Din Rail, Channel

1. Overview

DIN Rail and Channel Terminal Blocks are modular electrical connectors used to secure and transmit electrical signals or power between wires and devices. Designed to mount on standardized DIN rails (EN 50022) or channel rails, these components enable efficient wiring organization in industrial and commercial systems. Their importance lies in simplifying complex electrical installations, enhancing maintainability, and ensuring reliable connectivity in critical infrastructure.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Screw-Type DIN Rail Terminal BlocksUses screw clamping for secure wire connections; supports high current ratingsIndustrial control panels, HVAC systems
Spring-Clamp Terminal BlocksTool-free push-in wiring for fast installation; vibration-resistantAutomation systems, railway signaling
PCB Mount Terminal BlocksDirect printed circuit board integration; compact designTelecom equipment, medical devices
Channel Rail Terminal BlocksDesigned for C-shaped channel rails; modular expandabilityPower distribution cabinets, renewable energy systems

3. Structure and Components

Typical construction includes:

  • Conductive Elements: Copper alloy or brass contacts with tin/silver plating for corrosion resistance
  • Insulation Housing: Flame-retardant thermoplastic (UL 94 V-0 rated)
  • Mounting Mechanism: Snap-in clips for DIN rail (35mm standard) or channel rail compatibility
  • Wire Connection System: Screw terminals (M3-M4), spring clamps, or cage clamps

4. Key Technical Parameters

ParameterTypical RangeImportance
Rated Current10A - 100ADetermines power transmission capacity
Rated Voltage250V - 1000VDefines electrical insulation requirements
Wire Size Compatibility0.14mm - 300mm Matches with conductor dimensions
Insulation Resistance>1000M Ensures safety and signal integrity
Operating Temperature-20 C to +70 CMaterial performance under thermal stress

5. Application Fields

  • Industrial Automation: PLC control cabinets, motor drives
  • Energy Systems: Solar inverters, wind turbine junction boxes
  • Building Infrastructure: Smart lighting control systems
  • Rail Transport: Train power distribution panels

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Phoenix ContactPT 10-1.5/HC SeriesModular design with cross-connection capability
Weidm llerOMNIMATE PCB Terminal BlocksHigh-density PCB connectivity
Schneider ElectricEasy Connect DIN Rail BlocksIP20 protection rating, color-coded wiring
TE ConnectivityDIN-A-MITE SeriesCompact size with 6kV impulse withstand

7. Selection Guidelines

Key considerations:

  • Match current/voltage ratings with system requirements
  • Choose connection type based on maintenance needs (screw for high reliability, spring for quick changes)
  • Verify wire gauge compatibility
  • Consider environmental factors (temperature, vibration, humidity)
  • Check certifications (UL, CSA, IEC 60947)

Case Study: A smart building project selected spring-clamp terminal blocks with 600V rating and IP55 housing to enable rapid maintenance while ensuring safety in electrical rooms.

8. Industry Trends

  • Miniaturization: 30% reduction in standard DIN rail block width (e.g., 6.2mm vs. 8.4mm)
  • Smart Integration: Built-in current sensors and IoT connectivity
  • Material Innovation: Halogen-free flame retardant materials
  • Standardization: Global adoption of IEC 61535 for safe low-voltage connections
RFQ BOM Call Skype Email
Top