Terminal Blocks - Din Rail, Channel

Image Part Number Description / PDF Quantity Rfq
3044611

3044611

Phoenix Contact

CONN TERM BLK FEED THRU 10-26AWG

26

0719142

0719142

Phoenix Contact

CONN TERM BLK FEED THRU 12-28AWG

2

0443081

0443081

Phoenix Contact

CONN TERM BLK GROUND 12-30AWG

0

3045075

3045075

Phoenix Contact

CONN TERM BLK FEED THRU 12-26AWG

390310250

3212011

3212011

Phoenix Contact

CONN TERM BLK GROUND 12-26AWG

7

3044670

3044670

Phoenix Contact

CONN TERM BLK DISCONN 12-26AWG

0

3038875

3038875

Phoenix Contact

CONN TERM BLK DISCONN 10-28AWG

5100

3044762

3044762

Phoenix Contact

CONN TERM BLK DISCONN 10-26AWG

94

3211432

3211432

Phoenix Contact

CONN TERM BLK FEED THRU 12-26AWG

0

3038480

3038480

Phoenix Contact

CONN TERM BLK GROUND 12-28AWG

0

0441517

0441517

Phoenix Contact

CONN TERM BLK GROUND 10-26AWG

0

3044366

3044366

Phoenix Contact

CONN TERM BLK FEED THRU 10-26AWG

108

3048603

3048603

Phoenix Contact

CONN TERM BLK DISCONNECT 6-18AWG

4156

3050332

3050332

Phoenix Contact

CONN TERM BLK FEED THRU 14-20AWG

0

3036123

3036123

Phoenix Contact

CONN TERM BLK FEED THRU 6-16 AWG

1

3244449

3244449

Phoenix Contact

CONN TERM BLK FEED THRU 14-26AWG

3

3214367

3214367

Phoenix Contact

CONN TERM BLK DISCONN 10-26AWG

25

3038642

3038642

Phoenix Contact

CONN TERM BLK DISCONN 12-28AWG

0

3036039

3036039

Phoenix Contact

CONN TERM BLK GROUND 10-28AWG

0

3035698

3035698

Phoenix Contact

CONN TERM BLK FEED THRU 8-20 AWG

0

Terminal Blocks - Din Rail, Channel

1. Overview

DIN Rail and Channel Terminal Blocks are modular electrical connectors used to secure and transmit electrical signals or power between wires and devices. Designed to mount on standardized DIN rails (EN 50022) or channel rails, these components enable efficient wiring organization in industrial and commercial systems. Their importance lies in simplifying complex electrical installations, enhancing maintainability, and ensuring reliable connectivity in critical infrastructure.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Screw-Type DIN Rail Terminal BlocksUses screw clamping for secure wire connections; supports high current ratingsIndustrial control panels, HVAC systems
Spring-Clamp Terminal BlocksTool-free push-in wiring for fast installation; vibration-resistantAutomation systems, railway signaling
PCB Mount Terminal BlocksDirect printed circuit board integration; compact designTelecom equipment, medical devices
Channel Rail Terminal BlocksDesigned for C-shaped channel rails; modular expandabilityPower distribution cabinets, renewable energy systems

3. Structure and Components

Typical construction includes:

  • Conductive Elements: Copper alloy or brass contacts with tin/silver plating for corrosion resistance
  • Insulation Housing: Flame-retardant thermoplastic (UL 94 V-0 rated)
  • Mounting Mechanism: Snap-in clips for DIN rail (35mm standard) or channel rail compatibility
  • Wire Connection System: Screw terminals (M3-M4), spring clamps, or cage clamps

4. Key Technical Parameters

ParameterTypical RangeImportance
Rated Current10A - 100ADetermines power transmission capacity
Rated Voltage250V - 1000VDefines electrical insulation requirements
Wire Size Compatibility0.14mm - 300mm Matches with conductor dimensions
Insulation Resistance>1000M Ensures safety and signal integrity
Operating Temperature-20 C to +70 CMaterial performance under thermal stress

5. Application Fields

  • Industrial Automation: PLC control cabinets, motor drives
  • Energy Systems: Solar inverters, wind turbine junction boxes
  • Building Infrastructure: Smart lighting control systems
  • Rail Transport: Train power distribution panels

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Phoenix ContactPT 10-1.5/HC SeriesModular design with cross-connection capability
Weidm llerOMNIMATE PCB Terminal BlocksHigh-density PCB connectivity
Schneider ElectricEasy Connect DIN Rail BlocksIP20 protection rating, color-coded wiring
TE ConnectivityDIN-A-MITE SeriesCompact size with 6kV impulse withstand

7. Selection Guidelines

Key considerations:

  • Match current/voltage ratings with system requirements
  • Choose connection type based on maintenance needs (screw for high reliability, spring for quick changes)
  • Verify wire gauge compatibility
  • Consider environmental factors (temperature, vibration, humidity)
  • Check certifications (UL, CSA, IEC 60947)

Case Study: A smart building project selected spring-clamp terminal blocks with 600V rating and IP55 housing to enable rapid maintenance while ensuring safety in electrical rooms.

8. Industry Trends

  • Miniaturization: 30% reduction in standard DIN rail block width (e.g., 6.2mm vs. 8.4mm)
  • Smart Integration: Built-in current sensors and IoT connectivity
  • Material Innovation: Halogen-free flame retardant materials
  • Standardization: Global adoption of IEC 61535 for safe low-voltage connections
RFQ BOM Call Skype Email
Top