Terminal Blocks - Din Rail, Channel

Image Part Number Description / PDF Quantity Rfq
3210306

3210306

Phoenix Contact

CONN TERM BLK DISCONN 16-26AWG

0

3044077

3044077

Phoenix Contact

CONN TERM BLK FEED THRU 16-26AWG

342500

3044640

3044640

Phoenix Contact

CONN TERM BLK DISCONN 12-26AWG

0

1086509

1086509

Phoenix Contact

TERM BLOCK HIGH-CURRENT

5

3211771

3211771

Phoenix Contact

CONN TERM BLK FEED THRU 10-24AWG

1815

3248005

3248005

Phoenix Contact

CONN TERM BLK DISCONN 10-26AWG

85

3244559

3244559

Phoenix Contact

CONN TERM BLK ISOLATED 12-24 AWG

371200

2204231

2204231

Phoenix Contact

CONN TERM BLK DISCONNECT

12

3046249

3046249

Phoenix Contact

CONN TERM BLK DISCONN 10-26AWG

502650

3004430

3004430

Phoenix Contact

CONN TERM BLK DISCONN 12-22AWG

73

3210266

3210266

Phoenix Contact

CONN TERM BLK FEED THRU 12-26AWG

28

3208540

3208540

Phoenix Contact

CONN TERM BLK FEED THRU 14-26AWG

254

3244300

3244300

Phoenix Contact

CONN TERM BLK FEED THRU 12-28AWG

100250

0443052

0443052

Phoenix Contact

CONN TERM BLK GROUND 4-22 AWG

118

3209565

3209565

Phoenix Contact

CONN TERM BLK GROUND 12-26AWG

202

3209060

3209060

Phoenix Contact

CONN TERM BLK FEED THRU 12-28AWG

48

3209581

3209581

Phoenix Contact

CONN TERM BLK FEED THRU 12-26AWG

141425850

0790543

0790543

Phoenix Contact

CONN TERM BLK FEED THRU 14-26AWG

450

3046100

3046100

Phoenix Contact

CONN TERM BLK DISCONN 10-26AWG

545250

3031694

3031694

Phoenix Contact

CONN TERM BLK GROUND 10-28AWG

3

Terminal Blocks - Din Rail, Channel

1. Overview

DIN Rail and Channel Terminal Blocks are modular electrical connectors used to secure and transmit electrical signals or power between wires and devices. Designed to mount on standardized DIN rails (EN 50022) or channel rails, these components enable efficient wiring organization in industrial and commercial systems. Their importance lies in simplifying complex electrical installations, enhancing maintainability, and ensuring reliable connectivity in critical infrastructure.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Screw-Type DIN Rail Terminal BlocksUses screw clamping for secure wire connections; supports high current ratingsIndustrial control panels, HVAC systems
Spring-Clamp Terminal BlocksTool-free push-in wiring for fast installation; vibration-resistantAutomation systems, railway signaling
PCB Mount Terminal BlocksDirect printed circuit board integration; compact designTelecom equipment, medical devices
Channel Rail Terminal BlocksDesigned for C-shaped channel rails; modular expandabilityPower distribution cabinets, renewable energy systems

3. Structure and Components

Typical construction includes:

  • Conductive Elements: Copper alloy or brass contacts with tin/silver plating for corrosion resistance
  • Insulation Housing: Flame-retardant thermoplastic (UL 94 V-0 rated)
  • Mounting Mechanism: Snap-in clips for DIN rail (35mm standard) or channel rail compatibility
  • Wire Connection System: Screw terminals (M3-M4), spring clamps, or cage clamps

4. Key Technical Parameters

ParameterTypical RangeImportance
Rated Current10A - 100ADetermines power transmission capacity
Rated Voltage250V - 1000VDefines electrical insulation requirements
Wire Size Compatibility0.14mm - 300mm Matches with conductor dimensions
Insulation Resistance>1000M Ensures safety and signal integrity
Operating Temperature-20 C to +70 CMaterial performance under thermal stress

5. Application Fields

  • Industrial Automation: PLC control cabinets, motor drives
  • Energy Systems: Solar inverters, wind turbine junction boxes
  • Building Infrastructure: Smart lighting control systems
  • Rail Transport: Train power distribution panels

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Phoenix ContactPT 10-1.5/HC SeriesModular design with cross-connection capability
Weidm llerOMNIMATE PCB Terminal BlocksHigh-density PCB connectivity
Schneider ElectricEasy Connect DIN Rail BlocksIP20 protection rating, color-coded wiring
TE ConnectivityDIN-A-MITE SeriesCompact size with 6kV impulse withstand

7. Selection Guidelines

Key considerations:

  • Match current/voltage ratings with system requirements
  • Choose connection type based on maintenance needs (screw for high reliability, spring for quick changes)
  • Verify wire gauge compatibility
  • Consider environmental factors (temperature, vibration, humidity)
  • Check certifications (UL, CSA, IEC 60947)

Case Study: A smart building project selected spring-clamp terminal blocks with 600V rating and IP55 housing to enable rapid maintenance while ensuring safety in electrical rooms.

8. Industry Trends

  • Miniaturization: 30% reduction in standard DIN rail block width (e.g., 6.2mm vs. 8.4mm)
  • Smart Integration: Built-in current sensors and IoT connectivity
  • Material Innovation: Halogen-free flame retardant materials
  • Standardization: Global adoption of IEC 61535 for safe low-voltage connections
RFQ BOM Call Skype Email