Terminal Blocks - Accessories - Wire Ferrules

Image Part Number Description / PDF Quantity Rfq
FSD86-25-L

FSD86-25-L

Panduit Corporation

CONN FERRULE DIN 2AWG RED

625

FTD80-13-TL

FTD80-13-TL

Panduit Corporation

CONN FERRULE DIN TWO X 14AWG BLU

6352

FSD83-18-C

FSD83-18-C

Panduit Corporation

CONN FERRULE DIN 8AWG RED

49326900

FSF81-18-C

FSF81-18-C

Panduit Corporation

CONN FERRULE DIN 12AWG ORANGE

4

F85-18-C

F85-18-C

Panduit Corporation

CONN FERRULE DIN 4AWG

16388600

FSD73-8-D

FSD73-8-D

Panduit Corporation

CONN FERRULE DIN 24AWG YELLOW

2147483647

F81-18-M

F81-18-M

Panduit Corporation

CONN FERRULE DIN 12AWG

176537000

FSD85-18-L

FSD85-18-L

Panduit Corporation

CONN FERRULE DIN 4AWG YELLOW

91722800

F82-10-M

F82-10-M

Panduit Corporation

CONN FERRULE DIN 10AWG

5940

FTD84-16-C

FTD84-16-C

Panduit Corporation

CONN FERRULE DIN 6AWG BLUE

215

F78-18-M

F78-18-M

Panduit Corporation

CONN FERRULE DIN 16AWG

2000

FSDXL80-8-C

FSDXL80-8-C

Panduit Corporation

CONN FERRULE DIN 14AWG BLUE

140

FSD86-16-L

FSD86-16-L

Panduit Corporation

CONN FERRULE DIN 2AWG RED

2185550

F77-12-M

F77-12-M

Panduit Corporation

CONN FERRULE DIN 18AWG

242417000

FSD77-8-3K2

FSD77-8-3K2

Panduit Corporation

CONN FERRULE DIN 18AWG RED

2147483647

F82-12-M

F82-12-M

Panduit Corporation

CONN FERRULE DIN 10AWG

364613000

FSD75-8-3K10

FSD75-8-3K10

Panduit Corporation

CONN FERRULE DIN 20AWG WHITE

2147483647

FSD80-12-D

FSD80-12-D

Panduit Corporation

CONN FERRULE DIN 14AWG BLUE

3160

FSD73-6-D

FSD73-6-D

Panduit Corporation

CONN FERRULE DIN 24AWG YELLOW

2686

F84-25-TL

F84-25-TL

Panduit Corporation

CONN FERRULE DIN 6AWG

1915250

Terminal Blocks - Accessories - Wire Ferrules

1. Overview

Wire ferrules are tubular connectors used to terminate stranded wires, ensuring reliable electrical connections in terminal blocks. They compress the wire strands into a solid ring or eyelet, preventing fraying and improving conductivity. These components are critical in industrial automation, power distribution, and control systems where vibration resistance and long-term stability are essential.

2. Main Types & Functional Classification

TypeFunctional FeaturesApplication Examples
Open Barrel FerrulesAllow partial insertion of wires; suitable for frequent disassemblyControl panels in manufacturing systems
Insulated FerrulesInclude plastic sleeves for additional safety and insulationMedical equipment and HVAC systems
Double-Crimped FerrulesProvide dual compression points for enhanced mechanical strengthAutomotive wiring harnesses
Multi-Wire FerrulesAccommodate multiple wires in a single termination pointPower distribution boxes

3. Structure & Composition

Wire ferrules typically consist of: - Conductive Body: Made from electrolytic copper or brass for optimal conductivity - Surface Coating: Tin-plated for corrosion resistance and solderability - Insulation Sleeve: Thermoplastic material (e.g., PA66) for insulated types - Barrel Design: Precision-engineered inner diameter matching specific wire gauges

4. Key Technical Specifications

ParameterSignificance
Conductor Cross-Section Range (0.2-6 mm )Determines current-carrying capacity and wire compatibility
Rated Current (5-30 A)Defines maximum operational current under standard conditions
Crimping Force (50-200 N)Affects connection reliability and cold welding prevention
Temperature Range (-40 C to +120 C)Specifies operational limits in different environments
Material Hardness (60-90 HV)Influences durability and resistance to deformation

5. Application Fields

Primary industries include: - Industrial automation (PLC control cabinets, CNC machines) - Energy systems (solar inverters, wind turbine controllers) - Transportation (railway signaling systems, commercial vehicle wiring) - Building technology (HVAC systems, smart grid interfaces)

6. Leading Manufacturers & Products

ManufacturerRepresentative Product
Phoenix ContactMAU-SET series ferrules with push-in technology
Weidm llerKLUEGO color-coded ferrules for rail applications
TE ConnectivityDynamic ferrules for automotive vibration environments
WAGOTOPJOB S ferrules with integrated test points

7. Selection Recommendations

Key considerations: - Match ferrule inner diameter to stripped wire length (typically 0.5-1.0 mm tolerance) - Select material based on environmental factors (e.g., tin-plated for humid environments) - Consider insulation requirements per IEC 61558-1 standards - Verify compatibility with terminal block clamping mechanisms - For high-vibration applications, choose double-crimped designs

8. Industry Trends

Current developments include: - Miniaturization for PCB-mounted terminal blocks (down to 2.5 mm pitch) - Integration with smart diagnostic systems (e.g., temperature-sensing ferrules) - Adoption of halogen-free materials for improved fire safety - Development of hybrid ferrules combining power and signal transmission - Increased use of automated crimping systems in production lines