Fuses

Image Part Number Description / PDF Quantity Rfq
0477.800MXP

0477.800MXP

Wickmann / Littelfuse

FUSE CERAMIC 800MA 500VAC 400VDC

0

0219.630MXAP

0219.630MXAP

Wickmann / Littelfuse

FUSE GLASS 630MA 250VAC 5X20MM

895

37001000410

37001000410

Wickmann / Littelfuse

FUSE BRD MNT 100MA 250VAC RADIAL

2269

0874002.MXEP

0874002.MXEP

Wickmann / Littelfuse

FUSE CERAMIC 2A 250VAC AXIAL

0

0326007.VXP

0326007.VXP

Wickmann / Littelfuse

FUSE CERAMIC 7A 250VAC 3AB 3AG

510

0312025.HXP

0312025.HXP

Wickmann / Littelfuse

FUSE GLASS 25A 32VAC 3AB 3AG

100600

0216010.MXBP

0216010.MXBP

Wickmann / Littelfuse

FUSE CERAMIC 10A 250VAC 5X20MM

0

021606.3MXB940P

021606.3MXB940P

Wickmann / Littelfuse

FUSE CERAMIC 6.3A 250VAC 5X20MM

0

JCAS050.XP

JCAS050.XP

Wickmann / Littelfuse

FUSE AUTO 50A 32VAC/VDC AUTOLINK

1845

027401.5V

027401.5V

Wickmann / Littelfuse

FUSE BOARD MOUNT 1.5A 125VAC/VDC

20

0298450.ZXA

0298450.ZXA

Wickmann / Littelfuse

FUSE AUTO 450A 32VDC AUTO LINK

0

0472005.NAT1L

0472005.NAT1L

Wickmann / Littelfuse

FUSE BRD MNT 5A 125VAC/VDC AXIAL

0

0881080.UR

0881080.UR

Wickmann / Littelfuse

FUSE BOARD MOUNT 80A 75VDC

0

0312002.MXP

0312002.MXP

Wickmann / Littelfuse

FUSE GLASS 2A 250VAC 3AB 3AG

756

022902.5HXP

022902.5HXP

Wickmann / Littelfuse

FUSE GLASS 2.5A 250VAC 125VDC

333

0215005.MXF32P

0215005.MXF32P

Wickmann / Littelfuse

FUSE CERAMIC 5A 250VAC 5X20MM

0

0877002.MXEP

0877002.MXEP

Wickmann / Littelfuse

FUSE CERAMIC 2A 250VAC AXIAL

708

0471003.NRT1L

0471003.NRT1L

Wickmann / Littelfuse

FUSE BRD MNT 3A 125VAC/VDC AXIAL

5697

0218.630MRET1P

0218.630MRET1P

Wickmann / Littelfuse

FUSE GLASS 630MA 250VAC 5X20MM

0

37204000431

37204000431

Wickmann / Littelfuse

FUSE BOARD MNT 400MA 250VAC RAD

91

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures

RFQ BOM Call Skype Email
Top