Fuses

Image Part Number Description / PDF Quantity Rfq
0999040.ZXN

0999040.ZXN

Wickmann / Littelfuse

FUSE AUTO 40A 58VDC BLADE

0

0218001.VXP

0218001.VXP

Wickmann / Littelfuse

FUSE GLASS 1A 250VAC 5X20MM

0

0239004.VXP

0239004.VXP

Wickmann / Littelfuse

FUSE GLASS 4A 125VAC 5X20MM

0

0218008.HXP

0218008.HXP

Wickmann / Littelfuse

FUSE GLASS 8A 250VAC 5X20MM

0

046001.5ER

046001.5ER

Wickmann / Littelfuse

FUSE BRD MNT 1.5A 125VAC/VDC SMD

0

099707.5WXN

099707.5WXN

Wickmann / Littelfuse

FUSE AUTO 7.5A 58VDC BLADE MINI

0

2410SFV10.0FM/125-2

2410SFV10.0FM/125-2

Wickmann / Littelfuse

FUSE BRD MNT 10A 125VAC/VDC 2410

0

0299080.TXN

0299080.TXN

Wickmann / Littelfuse

FUSE AUTO 80A 32VDC BLADE

1490

031301.6VXP

031301.6VXP

Wickmann / Littelfuse

FUSE GLASS 1.6A 250VAC 3AB 3AG

75

0233001.MXEP

0233001.MXEP

Wickmann / Littelfuse

FUSE GLASS 1A 125VAC 5X20MM

0

015403.5DRTL

015403.5DRTL

Wickmann / Littelfuse

FUSE BRD MNT 3.5A 125VAC/VDC SMD

0

03121.75MXP

03121.75MXP

Wickmann / Littelfuse

FUSE GLASS 1.75A 250VAC 3AB 3AG

0

37321000000

37321000000

Wickmann / Littelfuse

FUSE BOARD MNT 10A 250VAC RADIAL

0

0313.010HXP

0313.010HXP

Wickmann / Littelfuse

FUSE GLASS 10MA 250VAC 3AB 3AG

100

0272.125V

0272.125V

Wickmann / Littelfuse

FUSE BOARD MNT 125MA 125VAC/VDC

0

0677.315MXE

0677.315MXE

Wickmann / Littelfuse

FUSE CERAMIC 315MA 250VAC AXIAL

0

0326.750VXP

0326.750VXP

Wickmann / Littelfuse

FUSE CERAMIC 750MA 250VAC 125VDC

0

0325.300HXP

0325.300HXP

Wickmann / Littelfuse

FUSE CERAMIC 300MA 250VAC 125VDC

0

0443003.DR

0443003.DR

Wickmann / Littelfuse

FUSE BOARD MOUNT 3A 250VAC 2SMD

3840

0402SFF100F/24-2

0402SFF100F/24-2

Wickmann / Littelfuse

FUSE BOARD MOUNT 1A 24VDC 0402

0

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures

RFQ BOM Call Skype Email
Top