Fuses

Image Part Number Description / PDF Quantity Rfq
0477005.MXF34P

0477005.MXF34P

Wickmann / Littelfuse

FUSE 500VAC 400VDC 5X20 TL 5A

0

02151.25MXEP

02151.25MXEP

Wickmann / Littelfuse

FUSE CERAMIC 1.25A 250VAC 5X20MM

570

ITV5432L1430

ITV5432L1430

Wickmann / Littelfuse

PTC RESETTABLE FUSE 14V 30A

29946000

0216004.MXESPP

0216004.MXESPP

Wickmann / Littelfuse

FUSE CERAMIC 4A 250VAC 5X20MM

694

0285020.MXRP

0285020.MXRP

Wickmann / Littelfuse

FUSE CERAMIC 20A 250VAC 5X20MM

0

0506020.MXP

0506020.MXP

Wickmann / Littelfuse

FUSE CERAMIC 20A 600VDC 3AB 3AG

0

0491002.MAT1

0491002.MAT1

Wickmann / Littelfuse

FUSE BRD MNT 2A 125VAC/VDC AXIAL

0

031301.5MXP

031301.5MXP

Wickmann / Littelfuse

FUSE GLASS 1.5A 250VAC 3AB 3AG

685

37312500000

37312500000

Wickmann / Littelfuse

FUSE BOARD MOUNT 2.5A 250VAC RAD

0

087406.3MRET1P

087406.3MRET1P

Wickmann / Littelfuse

FUSE CERAMIC 6.3A 250VAC AXIAL

0

021701.6TXP

021701.6TXP

Wickmann / Littelfuse

FUSE GLASS 1.6A 250VAC 5X20MM

0

02133.15TXP

02133.15TXP

Wickmann / Littelfuse

FUSE GLASS 3.15A 250VAC 5X20MM

0

0239003.MXF34P

0239003.MXF34P

Wickmann / Littelfuse

FUSE GLASS 3A 250VAC 5X20MM

0

0230004.HXAP

0230004.HXAP

Wickmann / Littelfuse

FUSE GLASS 4A 125VAC/VDC AXIAL

0

0498125.MXM6-CN

0498125.MXM6-CN

Wickmann / Littelfuse

FUSE MIDI 32V-DC 125A W/ M6 HOLE

0

027301.5H

027301.5H

Wickmann / Littelfuse

FUSE BOARD MOUNT 1.5A 125VAC/VDC

270

142.5631.5302

142.5631.5302

Wickmann / Littelfuse

FUSE AUTO 30A 58VDC AUTO LINK

228500

04773.15MXF11P

04773.15MXF11P

Wickmann / Littelfuse

FUSE CERAMIC 3.15A 500VAC 400VDC

0

0451012.NRL

0451012.NRL

Wickmann / Littelfuse

FUSE BRD MNT 12A 65VAC/VDC 2SMD

0

37311250410

37311250410

Wickmann / Littelfuse

FUSE BRD MNT 1.25A 250VAC RADIAL

49

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures

RFQ BOM Call Skype Email
Top