Fuses

Image Part Number Description / PDF Quantity Rfq
0203001.H

0203001.H

Wickmann / Littelfuse

FUSE BOARD MOUNT 1A 250VAC 2DIP

0

0437005.WRA

0437005.WRA

Wickmann / Littelfuse

FUSE 32V FA 1206 5A AECQ

0

37000500430

37000500430

Wickmann / Littelfuse

FUSE BOARD MOUNT 50MA 250VAC RAD

345

0235.300HXEP

0235.300HXEP

Wickmann / Littelfuse

FUSE GLASS 300MA 250VAC 5X20MM

0

046702.5NR

046702.5NR

Wickmann / Littelfuse

FUSE BRD MNT 2.5A 32VAC/VDC 0603

5284

02302.25VXP

02302.25VXP

Wickmann / Littelfuse

FUSE GLASS 2.25A 250VAC 125VDC

0

0239003.HXEP

0239003.HXEP

Wickmann / Littelfuse

FUSE GLASS 3A 250VAC 5X20MM

172

0215004.HXP

0215004.HXP

Wickmann / Littelfuse

FUSE CERAMIC 4A 250VAC 5X20MM

0

02153.15MXF59P

02153.15MXF59P

Wickmann / Littelfuse

FUSE CERAMIC 3.15A 250VAC 5X20MM

15000

0217.100TXP

0217.100TXP

Wickmann / Littelfuse

FUSE GLASS 100MA 250VAC 5X20MM

0

0263.125WRT1L

0263.125WRT1L

Wickmann / Littelfuse

FUSE BOARD MOUNT 125MA 250VAC

652

0451.160MRL

0451.160MRL

Wickmann / Littelfuse

FUSE BOARD MNT 160MA 125VAC/VDC

2401

02092.25MXEP

02092.25MXEP

Wickmann / Littelfuse

FUSE GLASS 2.25A 350VAC 2AG

0

046501.6DR

046501.6DR

Wickmann / Littelfuse

FUSE BOARD MNT 1.6A 250VAC 2SMD

1852

39211000000

39211000000

Wickmann / Littelfuse

FUSE BOARD MNT 1A 250VAC RADIAL

5388

0235.800VXEP

0235.800VXEP

Wickmann / Littelfuse

FUSE GLASS 800MA 250VAC 5X20MM

0

0215001.MXBP

0215001.MXBP

Wickmann / Littelfuse

FUSE CERAMIC 1A 250VAC 5X20MM

0

0FLQ005.H

0FLQ005.H

Wickmann / Littelfuse

FUSE CERAMIC 5A 500VAC/300VDC

0

39211600440

39211600440

Wickmann / Littelfuse

FUSE BRD MNT 1.6A 250VAC RADIAL

0

0326008.HXP

0326008.HXP

Wickmann / Littelfuse

FUSE CERAMIC 8A 250VAC 3AB 3AG

0

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures

RFQ BOM Call Skype Email
Top