Fuses

Image Part Number Description / PDF Quantity Rfq
0218.200MXP

0218.200MXP

Wickmann / Littelfuse

FUSE GLASS 200MA 250VAC 5X20MM

1000

80714000000

80714000000

Wickmann / Littelfuse

FUSE BOARD MOUNT 4A 300VAC RAD

1194

0318002.HXP

0318002.HXP

Wickmann / Littelfuse

FUSE GLASS 2A 250VAC 3AB 3AG

0

027701.5V

027701.5V

Wickmann / Littelfuse

FUSE BOARD MOUNT 1.5A 125VAC/VDC

0

0230.750MRT1SSP

0230.750MRT1SSP

Wickmann / Littelfuse

FUSE GLASS 750MA 250VAC 125VDC

0

02163.15HXP

02163.15HXP

Wickmann / Littelfuse

FUSE CERAMIC 3.15A 250VAC 5X20MM

37

37002000000

37002000000

Wickmann / Littelfuse

FUSE BOARD MNT 200MA 250VAC RAD

0

0251015.MRT1L

0251015.MRT1L

Wickmann / Littelfuse

FUSE BRD MNT 15A 32VAC/VDC AXIAL

813

JCAS020.XP

JCAS020.XP

Wickmann / Littelfuse

FUSE AUTO 20A 32VAC/VDC AUTOLINK

1175

048712.5MXEP

048712.5MXEP

Wickmann / Littelfuse

FUSE CERM 12.5A 420VAC/VDC AXIAL

0

0218004.MXP

0218004.MXP

Wickmann / Littelfuse

FUSE GLASS 4A 250VAC 5X20MM

4406

0459.062ER

0459.062ER

Wickmann / Littelfuse

FUSE BRD MNT 62MA 125VAC/VDC SMD

0

0325012.MXP

0325012.MXP

Wickmann / Littelfuse

FUSE CERM 12A 250VAC 60VDC 3AB

0

0215010.MX909P

0215010.MX909P

Wickmann / Littelfuse

FUSE CERAMIC 10A 250VAC 5X20MM

0

ITV4030L1415

ITV4030L1415

Wickmann / Littelfuse

PTC RESETTABLE FUSE 14V 15A

4415

37002500410

37002500410

Wickmann / Littelfuse

FUSE BOARD MNT 250MA 250VAC RAD

0

0275025.MRT1L

0275025.MRT1L

Wickmann / Littelfuse

FUSE BOARD MOUNT 25A 32VAC/VDC

1000

0229.500MXSP

0229.500MXSP

Wickmann / Littelfuse

FUSE GLASS 500MA 250VAC 125VDC

0

0215.200MRET1P

0215.200MRET1P

Wickmann / Littelfuse

FUSE CERAMIC 200MA 250VAC 5X20MM

0

0313007.VXIDP

0313007.VXIDP

Wickmann / Littelfuse

FUSE GLASS 7A 250VAC 3AB 3AG

0

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures

RFQ BOM Call Skype Email
Top