Fuses

Image Part Number Description / PDF Quantity Rfq
0454012.MR

0454012.MR

Wickmann / Littelfuse

FUSE BRD MNT 12A 72VAC 60VDC SMD

2147

031801.8MXP

031801.8MXP

Wickmann / Littelfuse

FUSE GLASS 1.8A 250VAC 3AB 3AG

0

0472.500MAT1L

0472.500MAT1L

Wickmann / Littelfuse

FUSE BOARD MNT 500MA 125VAC/VDC

0

0AGU010.T

0AGU010.T

Wickmann / Littelfuse

FUSE AGU 10A 32V 5AG

0

1206SFS450F/32-2

1206SFS450F/32-2

Wickmann / Littelfuse

FUSE BOARD MOUNT 4.5A 32VDC 1206

36

0435003.KR

0435003.KR

Wickmann / Littelfuse

FUSE BOARD MOUNT 3A 32VDC 0402

6625

0498040.MX1M6

0498040.MX1M6

Wickmann / Littelfuse

FUSE - MIDI 32VDC, M6 1-HOLE 40A

0

0216.160MXP

0216.160MXP

Wickmann / Littelfuse

FUSE CERAMIC 160MA 250VAC 5X20MM

0

0215.400HXP

0215.400HXP

Wickmann / Littelfuse

FUSE CERAMIC 400MA 250VAC 5X20MM

0

30311600001

30311600001

Wickmann / Littelfuse

FUSE BOARD MNT 1.6A 125VAC 63VDC

0

0AGC02.5V

0AGC02.5V

Wickmann / Littelfuse

FUSE GLASS 2.5A 32VAC/VDC 3AB

150

0494004.NRHF

0494004.NRHF

Wickmann / Littelfuse

FUSE BOARD MNT 4A 32VAC/VDC 0603

0

0326.600HXP

0326.600HXP

Wickmann / Littelfuse

FUSE CERAMIC 600MA 250VAC 125VDC

0

0213005.MXBF61P

0213005.MXBF61P

Wickmann / Littelfuse

FUSE GLASS 5A 250VAC 5X20MM

0

0216.080MXP

0216.080MXP

Wickmann / Littelfuse

FUSE CERAMIC 80MA 250VAC 5X20MM

0

0239.400VXEP

0239.400VXEP

Wickmann / Littelfuse

FUSE GLASS 400MA 250VAC 5X20MM

0

0874.300MXEP

0874.300MXEP

Wickmann / Littelfuse

FUSE CERAMIC 300MA 250VAC AXIAL

0

0324003.MXP

0324003.MXP

Wickmann / Littelfuse

FUSE CERM 3A 250VAC 125VDC 3AB

0

0AGU060.T

0AGU060.T

Wickmann / Littelfuse

FUSE AGU 60A 32V 5AG

37170

0218.063MXEP

0218.063MXEP

Wickmann / Littelfuse

FUSE GLASS 63MA 250VAC 5X20MM

0

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures

RFQ BOM Call Skype Email
Top