Fuses

Image Part Number Description / PDF Quantity Rfq
0216004.TXP

0216004.TXP

Wickmann / Littelfuse

FUSE CERAMIC 4A 250VAC 5X20MM

0

0215.800MRET1P

0215.800MRET1P

Wickmann / Littelfuse

FUSE CERAMIC 800MA 250VAC 5X20MM

0

0235006.HXP

0235006.HXP

Wickmann / Littelfuse

FUSE GLASS 6A 125VAC 5X20MM

130

0232003.MXF19P

0232003.MXF19P

Wickmann / Littelfuse

FUSE GLASS 3A 250VAC 5X20MM

0

0251.750MXL

0251.750MXL

Wickmann / Littelfuse

FUSE BOARD MNT 750MA 125VAC/VDC

1353

0314020.VXP

0314020.VXP

Wickmann / Littelfuse

FUSE CERM 20A 250VAC 125VDC 3AB

1935765

0263.375VXL

0263.375VXL

Wickmann / Littelfuse

FUSE BRD MNT 375MA 250VAC AXIAL

0

0332006.HXP

0332006.HXP

Wickmann / Littelfuse

FUSE CERM 6A 250VAC 125VDC 3AB

0

023902.5HXP

023902.5HXP

Wickmann / Littelfuse

FUSE GLASS 2.5A 250VAC 5X20MM

129

0999060.ZXN

0999060.ZXN

Wickmann / Littelfuse

FUSE AUTO 60A 58VDC BLADE

1249

39601000000

39601000000

Wickmann / Littelfuse

FUSE BRD MNT 100MA 125VAC RADIAL

1612

0216.125MXP

0216.125MXP

Wickmann / Littelfuse

FUSE CERAMIC 125MA 250VAC 5X20MM

0

37311250000

37311250000

Wickmann / Littelfuse

FUSE BRD MNT 1.25A 250VAC RADIAL

0

0315.375MXP

0315.375MXP

Wickmann / Littelfuse

FUSE GLASS 375MA 250VAC 3AB 3AG

0

142.5395.6302

142.5395.6302

Wickmann / Littelfuse

FUSE AUTO 300A 58VDC AUTO LINK

219

047302.5MAT1L

047302.5MAT1L

Wickmann / Littelfuse

FUSE BOARD MOUNT 2.5A 125VAC/VDC

0

0218001.MXP

0218001.MXP

Wickmann / Littelfuse

FUSE GLASS 1A 250VAC 5X20MM

1578

0498200.SXT

0498200.SXT

Wickmann / Littelfuse

FUSE AUTO 200A 32VDC AUTO LINK

0

021306.3MXBP

021306.3MXBP

Wickmann / Littelfuse

FUSE GLASS 6.3A 250VAC 5X20MM

0

02341.25MXBP

02341.25MXBP

Wickmann / Littelfuse

FUSE GLASS 1.25A 250VAC 5X20MM

0

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures

RFQ BOM Call Skype Email
Top