Fuses

Image Part Number Description / PDF Quantity Rfq
015401.6DRL

015401.6DRL

Wickmann / Littelfuse

FUSE BRD MNT 1.6A 125VAC/VDC SMD

0

047606.3MR

047606.3MR

Wickmann / Littelfuse

FUSE BRD MNT 6.3A 125VAC/VDC SMD

0

0218.800HXP

0218.800HXP

Wickmann / Littelfuse

FUSE GLASS 800MA 250VAC 5X20MM

0

0239.250MRET1P

0239.250MRET1P

Wickmann / Littelfuse

FUSE GLASS 250MA 250VAC 5X20MM

0

37400630000

37400630000

Wickmann / Littelfuse

FUSE BOARD MOUNT 63MA 250VAC RAD

0

0315.031MXP

0315.031MXP

Wickmann / Littelfuse

FUSE GLASS 31MA 250VAC 3AB 3AG

0

35612000029

35612000029

Wickmann / Littelfuse

FUSE CERAMIC 2A 440VAC 3AB 3AG

290

0314003.MXP

0314003.MXP

Wickmann / Littelfuse

FUSE CERM 3A 250VAC 125VDC 3AB

1051

0874008.MXEP

0874008.MXEP

Wickmann / Littelfuse

FUSE CERAMIC 8A 250VAC AXIAL

0

0235.500VXP

0235.500VXP

Wickmann / Littelfuse

FUSE GLASS 500MA 250VAC 5X20MM

0

0277003.M

0277003.M

Wickmann / Littelfuse

FUSE BRD MNT 3A 125VAC/VDC AXIAL

995

0216.500TXP

0216.500TXP

Wickmann / Littelfuse

FUSE CERAMIC 500MA 250VAC 5X20MM

0

025101.5NRT1L

025101.5NRT1L

Wickmann / Littelfuse

FUSE BOARD MOUNT 1.5A 125VAC/VDC

0

0452007.NRL

0452007.NRL

Wickmann / Littelfuse

FUSE BRD MNT 7A 72VAC 60VDC 2SMD

0

30315000421

30315000421

Wickmann / Littelfuse

FUSE BRD MNT 5A 125VAC 63VDC RAD

0

153.5395.6171

153.5395.6171

Wickmann / Littelfuse

FUSE AUTO 175A 32VDC

280

043501.5KRHF

043501.5KRHF

Wickmann / Littelfuse

FUSE BOARD MOUNT 1.5A 32VDC 0402

0

0997015.WXN

0997015.WXN

Wickmann / Littelfuse

FUSE AUTO 15A 58VDC BLADE MINI

4650

37001600430

37001600430

Wickmann / Littelfuse

FUSE BRD MNT 160MA 250VAC RADIAL

0

0448002.MR

0448002.MR

Wickmann / Littelfuse

FUSE BOARD MNT 2A 125VAC/VDC SMD

14153

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures

RFQ BOM Call Skype Email
Top