Fuses

Image Part Number Description / PDF Quantity Rfq
021606.3VXP

021606.3VXP

Wickmann / Littelfuse

FUSE CERAMIC 6.3A 250VAC 5X20MM

0

02351.25VXP

02351.25VXP

Wickmann / Littelfuse

FUSE GLASS 1.25A 250VAC 5X20MM

0

0476012.MR

0476012.MR

Wickmann / Littelfuse

FUSE BRD MNT 12A 125VAC/VDC SMD

0

02200010MRT1P

02200010MRT1P

Wickmann / Littelfuse

FUSE GLASS 550MA 250VAC 125VDC

0

0253010.V

0253010.V

Wickmann / Littelfuse

FUSE BOARD MOUNT 10A 125VAC/VDC

0

0251010.NRT1L

0251010.NRT1L

Wickmann / Littelfuse

FUSE BOARD MOUNT 10A 125VAC/VDC

4590

0215012.MXBP

0215012.MXBP

Wickmann / Littelfuse

FUSE CERAMIC 12A 250VAC 5X20MM

0

0251005.VXL

0251005.VXL

Wickmann / Littelfuse

FUSE BRD MNT 5A 125VAC/VDC AXIAL

5

0299060.TXN

0299060.TXN

Wickmann / Littelfuse

FUSE AUTO 60A 32VDC BLADE

402550

39803150000

39803150000

Wickmann / Littelfuse

FUSE BOARD MOUNT 315MA 65VAC/VDC

0

2206.750HXP

2206.750HXP

Wickmann / Littelfuse

FUSE GLASS 750MA 300VAC 2AG

0

0471002.NRT1L

0471002.NRT1L

Wickmann / Littelfuse

FUSE BRD MNT 2A 125VAC/VDC AXIAL

0

0494.500NRHF

0494.500NRHF

Wickmann / Littelfuse

FUSE BOARD MOUNT 500MA 32VAC/VDC

0

0463025.ER

0463025.ER

Wickmann / Littelfuse

FUSE BRDMT 25A 250VAC/100VDC SMD

2660

0297020.WXNV

0297020.WXNV

Wickmann / Littelfuse

FUSE AUTO 20A 32VDC BLADE MINI

22085

0407004.WR

0407004.WR

Wickmann / Littelfuse

FUSE 1206 63V T-LAG 4A

2963

37302500410

37302500410

Wickmann / Littelfuse

FUSE BOARD MNT 250MA 250VAC RAD

0

0603SFP400F/32-2

0603SFP400F/32-2

Wickmann / Littelfuse

FUSE BOARD MOUNT 4A 32VDC 0603

0

39612000000

39612000000

Wickmann / Littelfuse

FUSE BOARD MOUNT 2A 125VAC RAD

65

0215008.MXF103SPP

0215008.MXF103SPP

Wickmann / Littelfuse

FUSE CERAMIC 8A 250VAC RADIAL

0

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures

RFQ BOM Call Skype Email
Top