Fuses

Image Part Number Description / PDF Quantity Rfq
021506.3MXF155SPP

021506.3MXF155SPP

Wickmann / Littelfuse

FUSE CERAMIC 6.3A 250VAC RADIAL

0

0875005.MXEP

0875005.MXEP

Wickmann / Littelfuse

FUSE CERAMIC 5A 250VAC AXIAL

177

38216300410

38216300410

Wickmann / Littelfuse

FUSE BOARD MOUNT 6.3A 250VAC RAD

0

0202005.H

0202005.H

Wickmann / Littelfuse

FUSE BOARD MOUNT 5A 250VAC 2DIP

600

0437.250WR

0437.250WR

Wickmann / Littelfuse

FUSE BOARD MNT 250MA 125VAC/VDC

0

050702.5MXP

050702.5MXP

Wickmann / Littelfuse

FUSE CERAMIC 2.5A 650VDC SMD

1000

0FLQ015.HXR

0FLQ015.HXR

Wickmann / Littelfuse

FUSE GLASS 15A 500VAC 5AG

0

0313010.HXP

0313010.HXP

Wickmann / Littelfuse

FUSE GLASS 10A 32VAC 3AB 3AG

0

0313008.HXP

0313008.HXP

Wickmann / Littelfuse

FUSE GLASS 8A 250VAC 3AB 3AG

0

37211000511

37211000511

Wickmann / Littelfuse

FUSE BOARD MNT 1A 250VAC RADIAL

0

153.5631.6101

153.5631.6101

Wickmann / Littelfuse

FUSE AUTO 100A 32VDC AUTO LINK

591410

37308000430

37308000430

Wickmann / Littelfuse

FUSE BOARD MNT 800MA 250VAC RAD

0

0477001.MXF34P

0477001.MXF34P

Wickmann / Littelfuse

FUSE 500VAC 400VDC 5X20 TL 1A

0

0875.250MRET1P

0875.250MRET1P

Wickmann / Littelfuse

FUSE CERAMIC 250MA 250VAC AXIAL

0

0239002.MRET1P

0239002.MRET1P

Wickmann / Littelfuse

FUSE GLASS 2A 250VAC 5X20MM

0

0219004.MXABP

0219004.MXABP

Wickmann / Littelfuse

FUSE GLASS 4A 250VAC 5X20MM

0

021612.5MRET3P

021612.5MRET3P

Wickmann / Littelfuse

FUSE 250V 5X20 IEC FA TR 12.5A

0

0514010.MXEP

0514010.MXEP

Wickmann / Littelfuse

FUSE CERAMIC 10A 500VAC 3AB 3AG

0

087401.5MXEP

087401.5MXEP

Wickmann / Littelfuse

FUSE CERAMIC 1.5A 250VAC AXIAL

0

39106300000

39106300000

Wickmann / Littelfuse

FUSE BRD MNT 630MA 65VAC/VDC RAD

0

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures