Fuses

Image Part Number Description / PDF Quantity Rfq
0977016.MXEP

0977016.MXEP

Wickmann / Littelfuse

FUSE CERM 16A 500VAC 450VDC 5X20

0

022903.5MXSP

022903.5MXSP

Wickmann / Littelfuse

FUSE GLASS 3.5A 250VAC 125VDC

0

35415000029

35415000029

Wickmann / Littelfuse

FUSE CERAMIC 5A 440VAC 3AB 3AG

114

0229006.HXSP

0229006.HXSP

Wickmann / Littelfuse

FUSE GLASS 6A 125VAC/VDC 2AG

0

0473.500YRT1L

0473.500YRT1L

Wickmann / Littelfuse

FUSE BOARD MNT 500MA 125VAC/VDC

0

0313001.HXIDP

0313001.HXIDP

Wickmann / Littelfuse

FUSE GLASS 1A 250VAC 3AB 3AG

0

0498023.M

0498023.M

Wickmann / Littelfuse

FUSE AUTO 23A 32VDC AUTO LINK

662

0312003.MXP

0312003.MXP

Wickmann / Littelfuse

FUSE GLASS 3A 250VAC 3AB 3AG

2131

1206SFF800F/24-2

1206SFF800F/24-2

Wickmann / Littelfuse

FUSE BOARD MOUNT 8A 24VDC 1206

603

0251.375MXL

0251.375MXL

Wickmann / Littelfuse

FUSE BOARD MNT 375MA 125VAC/VDC

971

0322015.MXP

0322015.MXP

Wickmann / Littelfuse

FUSE CERM 15A 65VAC/VDC 3AB 3AG

0

0218.800MXBP

0218.800MXBP

Wickmann / Littelfuse

FUSE GLASS 800MA 250VAC 5X20MM

0

0337010.LXS

0337010.LXS

Wickmann / Littelfuse

FUSE MICRO3 BLADE 32V AG 10A

2115

0219.315MXAP

0219.315MXAP

Wickmann / Littelfuse

FUSE GLASS 315MA 250VAC 5X20MM

0

39511000000

39511000000

Wickmann / Littelfuse

FUSE BOARD MNT 1A 125VAC RADIAL

1077

0213.200MXEP

0213.200MXEP

Wickmann / Littelfuse

FUSE GLASS 200MA 250VAC 5X20MM

0

0326.200VXP

0326.200VXP

Wickmann / Littelfuse

FUSE CERM 200MA 250VAC 3AB 3AG

0

0230002.HXSP

0230002.HXSP

Wickmann / Littelfuse

FUSE GLASS 2A 250VAC/125VDC AXL

0

04761.25MRSN

04761.25MRSN

Wickmann / Littelfuse

FUSE BRD MNT 250VAC/125VDC 2SMD

0

37403150000

37403150000

Wickmann / Littelfuse

FUSE BOARD MNT 315MA 250VAC RAD

0

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures

RFQ BOM Call Skype Email
Top