Fuses

Image Part Number Description / PDF Quantity Rfq
BK1/GMA-100-R

BK1/GMA-100-R

PowerStor (Eaton)

FUSE GLASS 100MA 250VAC 5X20MM

799

BK/GMA-15-R

BK/GMA-15-R

PowerStor (Eaton)

FUSE GLASS 15A 125VAC 5X20MM

1876500

BK/GDA-160MA

BK/GDA-160MA

PowerStor (Eaton)

FUSE CERAMIC 160MA 250VAC 5X20MM

0

AGC-V-175/1000R

AGC-V-175/1000R

PowerStor (Eaton)

BUSS SMALL DIMENSION FUSE

0

BK/MDQ-1/4

BK/MDQ-1/4

PowerStor (Eaton)

FUSE GLASS 250MA 250VAC 3AB 3AG

100

BK/AGC-V-4/10

BK/AGC-V-4/10

PowerStor (Eaton)

FUSE GLASS 400MA 250VAC 3AB 3AG

0

BK/C518S-250-R

BK/C518S-250-R

PowerStor (Eaton)

FUSE GLASS 250MA 250VAC 2AG

0

BK/ABC-4-R

BK/ABC-4-R

PowerStor (Eaton)

FUSE CERM 4A 250VAC 125VDC 3AB

1226900

BK/MDQ-12

BK/MDQ-12

PowerStor (Eaton)

FUSE GLASS 12A 32VAC 3AB 3AG

0

TR2/C515S-5-R

TR2/C515S-5-R

PowerStor (Eaton)

FUSE GLASS 5A 125VAC 2AG

0

BK/GBB-1-R

BK/GBB-1-R

PowerStor (Eaton)

FUSE CERM 1A 250VAC/125VDC 3AB

195

S500-80-R

S500-80-R

PowerStor (Eaton)

FUSE GLASS 80MA 250VAC 5X20MM

0

PCI-5-R

PCI-5-R

PowerStor (Eaton)

FUSE BOARD MNT 5A 125VAC/400VDC

0

BK/ABC-V-4-R

BK/ABC-V-4-R

PowerStor (Eaton)

FUSE CERM 4A 250VAC 125VDC 3AB

0

BK/AGC-7GG

BK/AGC-7GG

PowerStor (Eaton)

FUSE GLASS 7A 250VAC 3AB 3AG

0

BK/GDC-250MA

BK/GDC-250MA

PowerStor (Eaton)

FUSE GLASS 250MA 250VAC 5X20MM

0

SS-5-2A-BK

SS-5-2A-BK

PowerStor (Eaton)

FUSE BOARD MOUNT 2A 250VAC RAD

0

TR/3216FF2-R

TR/3216FF2-R

PowerStor (Eaton)

FUSE BRD MNT 2A 32VAC 63VDC 1206

73157

BK/S506-V-2-R

BK/S506-V-2-R

PowerStor (Eaton)

FUSE GLASS 2A 250VAC 5X20MM

0

MDL-V-9-R

MDL-V-9-R

PowerStor (Eaton)

FUSE GLASS 9A 32VAC 3AB 3AG

0

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures

RFQ BOM Call Skype Email
Top