Fuses

Image Part Number Description / PDF Quantity Rfq
MDA-V-3-R

MDA-V-3-R

PowerStor (Eaton)

FUSE CERAMIC 3A 250VAC 3AB 3AG

0

BK/GMD-300MA

BK/GMD-300MA

PowerStor (Eaton)

FUSE GLASS 300MA 250VAC 5X20MM

0

AGC-14-R

AGC-14-R

PowerStor (Eaton)

FUSE GLASS 14A 32VAC 3AB 3AG

0

BK/GMC-V-500-R

BK/GMC-V-500-R

PowerStor (Eaton)

FUSE GLASS 500MA 250VAC 5X20MM

0

BK/S500-100-R

BK/S500-100-R

PowerStor (Eaton)

FUSE GLASS 100MA 250VAC 5X20MM

31

TR2/6125FF8-R

TR2/6125FF8-R

PowerStor (Eaton)

FUSE BRD MNT 125VAC/72VDC 2410

0

BK/C519-4-R

BK/C519-4-R

PowerStor (Eaton)

FUSE GLASS 4A 125VAC 2AG

100

AGC-35-R

AGC-35-R

PowerStor (Eaton)

FUSE GLASS 35A 32VAC 3AB 3AG

0

BK/S506-630-R

BK/S506-630-R

PowerStor (Eaton)

FUSE GLASS 630MA 250VAC 5X20MM

144

TR/3216FF25-R

TR/3216FF25-R

PowerStor (Eaton)

FUSE BOARD MOUNT 25A 24VDC 1206

2612

SS-5-630MA-AP

SS-5-630MA-AP

PowerStor (Eaton)

FUSE BOARD MNT 630MA 250VAC RAD

975

BK/AGC-V-6/10

BK/AGC-V-6/10

PowerStor (Eaton)

FUSE GLASS 600MA 250VAC 3AB 3AG

0

SR-5-250MA-AP

SR-5-250MA-AP

PowerStor (Eaton)

FUSE BOARD MNT 250MA 250VAC RAD

920

BK/GMC-V-630-R

BK/GMC-V-630-R

PowerStor (Eaton)

FUSE GLASS 630MA 250VAC 5X20MM

0

AGC-4-1/2-R

AGC-4-1/2-R

PowerStor (Eaton)

FUSE GLASS 4.5A 250VAC 3AB 3AG

0

BK/GMW-1/10

BK/GMW-1/10

PowerStor (Eaton)

FUSE BRD MNT 100MA 125VAC RADIAL

0

BK1/S500-1.6-R

BK1/S500-1.6-R

PowerStor (Eaton)

FUSE GLASS 1.6A 250VAC 5X20MM

991

BK/GDC-100MA

BK/GDC-100MA

PowerStor (Eaton)

FUSE GLASS 100MA 250VAC 5X20MM

0

BK1/S505-2-R

BK1/S505-2-R

PowerStor (Eaton)

FUSE CERAMIC 2A 250VAC 5X20MM

0

BK/C518-4-R

BK/C518-4-R

PowerStor (Eaton)

FUSE GLASS 4A 250VAC 2AG

0

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures

RFQ BOM Call Skype Email