Fuses

Image Part Number Description / PDF Quantity Rfq
AGC-V-3/10-R

AGC-V-3/10-R

PowerStor (Eaton)

FUSE GLASS 300MA 250VAC 3AB 3AG

0

PCH-1-1/2-R

PCH-1-1/2-R

PowerStor (Eaton)

FUSE BRD MNT 1.5A 250VAC 450VDC

0

BK/MDL-5-R

BK/MDL-5-R

PowerStor (Eaton)

FUSE GLASS 5A 250VAC 3AB 3AG

143

BK/GFA-4

BK/GFA-4

PowerStor (Eaton)

FUSE BOARD MOUNT 4A 125VAC AXIAL

0

TR/3216FF30-R

TR/3216FF30-R

PowerStor (Eaton)

FUSE BOARD MOUNT 30A 24VDC 1206

2786

1025HC50-RTR

1025HC50-RTR

PowerStor (Eaton)

FUSE BOARD MOUNT 50A 60VAC 2SMD

3970

MDL-3-R

MDL-3-R

PowerStor (Eaton)

FUSE GLASS 3A 250VAC 3AB 3AG

0

BK-S505H-V-3.15-R

BK-S505H-V-3.15-R

PowerStor (Eaton)

FUSE CERAMIC 3.15A 600VAC 400VDC

0

MDL-2-1/2-R

MDL-2-1/2-R

PowerStor (Eaton)

FUSE GLASS 2.5A 250VAC 3AB 3AG

400

BK/S506-V-125-R

BK/S506-V-125-R

PowerStor (Eaton)

FUSE GLASS 125MA 250VAC 5X20MM

0

ABC-12-R

ABC-12-R

PowerStor (Eaton)

FUSE CERM 12A 250VAC 125VDC 3AB

605

BK/C515S-4-R

BK/C515S-4-R

PowerStor (Eaton)

FUSE GLASS 4A 125VAC 2AG

0

BK/C520-125-R

BK/C520-125-R

PowerStor (Eaton)

FUSE GLASS 125MA 250VAC 2AG

903

BK/C515S-1.25-R

BK/C515S-1.25-R

PowerStor (Eaton)

FUSE GLASS 1.25A 250VAC 2AG

0

BK/S505-2-R

BK/S505-2-R

PowerStor (Eaton)

FUSE CERAMIC 2A 250VAC 5X20MM

4287

BK/GDA-125MA

BK/GDA-125MA

PowerStor (Eaton)

FUSE CERAMIC 125MA 250VAC 5X20MM

0

MDL-5-R

MDL-5-R

PowerStor (Eaton)

FUSE GLASS 5A 250VAC 3AB 3AG

0

S500-50-R

S500-50-R

PowerStor (Eaton)

FUSE GLASS 50MA 250VAC 5X20MM

0

BK/AGC-2-1/4-R

BK/AGC-2-1/4-R

PowerStor (Eaton)

FUSE GLASS 2.25A 250VAC 3AB 3AG

62

BK/AGX-1/10

BK/AGX-1/10

PowerStor (Eaton)

FUSE GLASS 100MA 250VAC 8AG

25

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures

RFQ BOM Call Skype Email
Top