Fuses

Image Part Number Description / PDF Quantity Rfq
BK1/S501-1.6-R

BK1/S501-1.6-R

PowerStor (Eaton)

FUSE CERAMIC 1.6A 250VAC 5X20MM

930

TR2/6125FF15-R

TR2/6125FF15-R

PowerStor (Eaton)

FUSE BOARD MNT 15A 125VAC 72VDC

1345

GBB-V-20-R

GBB-V-20-R

PowerStor (Eaton)

FUSE CERM 20A 250VAC 125VDC 3AB

0

BK/MDL-4-R

BK/MDL-4-R

PowerStor (Eaton)

FUSE GLASS 4A 250VAC 3AB 3AG

1157

GMC-800-R

GMC-800-R

PowerStor (Eaton)

FUSE GLASS 800MA 250VAC 5X20MM

0

PCC-3-R

PCC-3-R

PowerStor (Eaton)

FUSE BOARD MNT 3A 250VAC/450VDC

35

BK/GBB-7-R

BK/GBB-7-R

PowerStor (Eaton)

FUSE CERM 7A 250VAC/125VDC 3AB

492

GMA-6-R

GMA-6-R

PowerStor (Eaton)

FUSE GLASS 6A 125VAC 5X20MM

0

BK/GMD-200-R

BK/GMD-200-R

PowerStor (Eaton)

FUSE GLASS 200MA 250VAC 5X20MM

794

BK/S506-200-R

BK/S506-200-R

PowerStor (Eaton)

FUSE GLASS 200MA 250VAC 5X20MM

151

BK/MDL-12-R

BK/MDL-12-R

PowerStor (Eaton)

FUSE GLASS 12A 32VAC 3AB 3AG

150

MDA-4-R

MDA-4-R

PowerStor (Eaton)

FUSE CERAMIC 4A 250VAC 3AB 3AG

235

ABC-1-1/2-R

ABC-1-1/2-R

PowerStor (Eaton)

FUSE CERM 1.5A 250VAC 125VDC 3AB

0

BK-S505SCH-5-R

BK-S505SCH-5-R

PowerStor (Eaton)

FUSE CERAMIC 5A 250VDC 5X20MM

732

BK/GDA-4A

BK/GDA-4A

PowerStor (Eaton)

FUSE CERAMIC 4A 250VAC 5X20MM

900

BK/AGC-2-1/2-R

BK/AGC-2-1/2-R

PowerStor (Eaton)

FUSE GLASS 2.5A 250VAC 3AB 3AG

593

GMA-1-R

GMA-1-R

PowerStor (Eaton)

FUSE GLASS 1A 250VAC 5X20MM

7115

SR-5-2.5A-AP

SR-5-2.5A-AP

PowerStor (Eaton)

FUSE BOARD MOUNT 2.5A 250VAC RAD

984

MDA-1/32

MDA-1/32

PowerStor (Eaton)

FUSE CERAMIC 32MA 250VAC 3AB 3AG

0

BK/GDC-V-1A

BK/GDC-V-1A

PowerStor (Eaton)

FUSE GLASS 1A 250VAC 5X20MM

0

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures

RFQ BOM Call Skype Email
Top