Fuses

Image Part Number Description / PDF Quantity Rfq
3413.0115.26

3413.0115.26

Schurter

FUSE BRD MNT 1A 32VAC 63VDC 1206

0

0034.7203

0034.7203

Schurter

FUSE BOARD MOUNT 63MA 250VAC RAD

99

0034.3763

0034.3763

Schurter

FUSE GLASS 125MA 250VAC 5X20MM

0

3404.0010.11

3404.0010.11

Schurter

FUSE BOARD MNT 1.25A 125VAC/VDC

322

3413.0221.22

3413.0221.22

Schurter

FUSE BOARD MNT 3.15A 32VAC 63VDC

890

3402.0005.24

3402.0005.24

Schurter

FUSE BRD MNT 160MA 63VAC/VDC SMD

0

0034.5609.22

0034.5609.22

Schurter

FUSE GLASS 160MA 250VAC 5X20MM

0

7010.6360.13

7010.6360.13

Schurter

FUSE BRD MNT 1A 125VAC/VDC AXIAL

397

3403.0016.24

3403.0016.24

Schurter

FUSE BRD MNT 1A 250VAC/VDC 2SMD

6337

7010.6420.13

7010.6420.13

Schurter

FUSE BRD MNT 5A 125VAC/VDC AXIAL

199

3413.0123.26

3413.0123.26

Schurter

FUSE BRD MNT 4A 32VAC 63VDC 1206

0

3404.2322.22

3404.2322.22

Schurter

FUSE BOARD MNT 500MA 125VAC/VDC

0

7100.1066.13

7100.1066.13

Schurter

FUSE BOARD MNT 1.25A 250VAC/VDC

100

0034.5712.11

0034.5712.11

Schurter

FUSE GLASS 800MA 250VAC 5X20MM

87

3403.0175.24

3403.0175.24

Schurter

FUSE BOARD MNT 8A 250VAC 125VDC

2682

3404.0012.24

3404.0012.24

Schurter

FUSE BOARD MNT 2A 125VAC/VDC SMD

2811

0034.5705.11

0034.5705.11

Schurter

FUSE GLASS 160MA 250VAC 5X20MM

0

7010.3430

7010.3430

Schurter

FUSE GLASS 1.6A 125VAC 5X20MM

160

3402.0016.11

3402.0016.11

Schurter

FUSE BOARD MNT 4A 63VAC/VDC 2SMD

13331000

8020.5017.G

8020.5017.G

Schurter

SHT 6.3X32 FUSE 4A T

903

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures

RFQ BOM Call Skype Email
Top