Fuses

Image Part Number Description / PDF Quantity Rfq
7100.1173.95

7100.1173.95

Schurter

FUSE BOARD MOUNT 6.3A 250VAC RAD

0

3402.0005.22

3402.0005.22

Schurter

FUSE BRD MNT 160MA 63VAC/VDC SMD

0

7010.9914.57

7010.9914.57

Schurter

FUSE BRD MNT 7A 63VAC 125VDC SMD

0

0034.6806

0034.6806

Schurter

FUSE BRD MNT 125MA 250VAC 125VDC

2222

3403.0017.24

3403.0017.24

Schurter

FUSE BOARD MNT 1.25A 250VAC/VDC

0

8020.5070

8020.5070

Schurter

FUSE CERAMIC 1.6A 500VAC 3AB 3AG

123

0034.3104.PT

0034.3104.PT

Schurter

FUSE GLASS 50MA 250VAC 5X20MM

0

0034.6951

0034.6951

Schurter

FUSE BOARD MOUNT 4A 250VAC RAD

63

3402.0020.11

3402.0020.11

Schurter

FUSE BOARD MNT 8A 63VAC/VDC 2SMD

1038

3403.0170.11

3403.0170.11

Schurter

FUSE BRD MNT 2.5A 250VAC 125VDC

545

3403.0167.11

3403.0167.11

Schurter

FUSE BRD MNT 1.25A 250VAC 125VDC

1110

0001.1026

0001.1026

Schurter

FUSE GLASS 1.6A 250VAC 3AB 3AG

93

0034.7118

0034.7118

Schurter

FUSE BOARD MOUNT 2A 250VAC RAD

200

0034.1513

0034.1513

Schurter

FUSE GLASS 500MA 250VAC 5X20MM

5203

0034.1531

0034.1531

Schurter

FUSE GLASS 80MA 250VAC 5X20MM

1939

0034.6031

0034.6031

Schurter

FUSE BOARD MOUNT 50MA 250VAC RAD

868

0034.5045

0034.5045

Schurter

FUSE GLASS 1.6A 250VAC 5X20MM

200

0034.1006

0034.1006

Schurter

FUSE GLASS 4A 250VAC 3AB 3AG

100

3413.0009.22

3413.0009.22

Schurter

FUSE BRD MNT 200MA 125VAC 63VDC

16839

0034.6045

0034.6045

Schurter

FUSE BRD MNT 1.25A 250VAC RADIAL

295

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures

RFQ BOM Call Skype Email
Top