Fuses

Image Part Number Description / PDF Quantity Rfq
0034.5710.22

0034.5710.22

Schurter

FUSE GLASS 500MA 250VAC 5X20MM

0

0034.6071

0034.6071

Schurter

FUSE BOARD MNT 500MA 250VAC RAD

740

3402.0040.22

3402.0040.22

Schurter

FUSE BRD MNT 10A 63VAC/VDC 2SMD

1635

3422.0015.11

3422.0015.11

Schurter

FUSE BRD MNT 3.5A 63VAC/VDC SMD

100

0034.5605.22

0034.5605.22

Schurter

FUSE GLASS 63MA 250VAC 5X20MM

0

8020.5072.PT

8020.5072.PT

Schurter

FUSE CERAMIC 2.5A 500VAC 3AB 3AG

982

7010.9969.63

7010.9969.63

Schurter

FUSE BOARD MOUNT 6.3A 125VAC/VDC

885

3422.0046.11

3422.0046.11

Schurter

FUSE BRD MNT 750MA 63VAC/VDC SMD

75

3422.0009.11

3422.0009.11

Schurter

FUSE BOARD MNT 1A 63VAC/VDC 2SMD

0

0034.6603

0034.6603

Schurter

FUSE BRD MNT 63MA 250VAC 125VDC

59

3403.0267.23

3403.0267.23

Schurter

UMT-H FUSE 200MA T

0

3404.0119.24

3404.0119.24

Schurter

FUSE BRD MNT 3.5A 125VAC/VDC SMD

0

0034.1527

0034.1527

Schurter

FUSE GLASS 32MA 250VAC 5X20MM

29714000

0034.5628.11

0034.5628.11

Schurter

FUSE GLASS 12.5A 250VAC 5X20MM

273

SUT-H-6332-20A00-CTG-TT-NI

SUT-H-6332-20A00-CTG-TT-NI

Schurter

SUT-H CARTRIDGE FUSE, 6.3X32 MM,

733300

0034.5621.11

0034.5621.11

Schurter

FUSE GLASS 2.5A 250VAC 5X20MM

116

3404.0020.22

3404.0020.22

Schurter

FUSE BRD MNT 8A 125VAC/VDC 2SMD

510

0034.5607.11

0034.5607.11

Schurter

FUSE GLASS 100MA 250VAC 5X20MM

362

0034.6915

0034.6915

Schurter

FUSE BOARD MNT 1A 250VAC RADIAL

43111700

7030.3140

7030.3140

Schurter

FUSE GLASS 63MA 220VAC 125VDC

62

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures

RFQ BOM Call Skype Email
Top