Fuses

Image Part Number Description / PDF Quantity Rfq
0251002.PARL

0251002.PARL

Wickmann / Littelfuse

FUSE BRD MNT 2A 125VAC/VDC AXIAL

0

0325.500MXP

0325.500MXP

Wickmann / Littelfuse

FUSE CERAMIC 500MA 250VAC 125VDC

0

SF-1206S400W-2

SF-1206S400W-2

J.W. Miller / Bourns

FUSE BOARD MOUNT 4A 65VDC 1206

3070

APS-10A

APS-10A

OptiFuse

FUSE AUTO 10A 32VDC BLADE MINI

2183

0326010.HXP

0326010.HXP

Wickmann / Littelfuse

FUSE CERAMIC 10A 250VAC 3AB 3AG

61611200

0315008.MXP

0315008.MXP

Wickmann / Littelfuse

FUSE GLASS 8A 250VAC 3AB 3AG

0

0218004.MXF11P

0218004.MXF11P

Wickmann / Littelfuse

FUSE GLASS 4A 250VAC 5X20MM

0

025103.5NAT6L

025103.5NAT6L

Wickmann / Littelfuse

FUSE BOARD MOUNT 3.5A 125VAC/VDC

0

0467.500NR

0467.500NR

Wickmann / Littelfuse

FUSE BOARD MOUNT 500MA 32VAC/VDC

4281

MFU0805FF00750P500

MFU0805FF00750P500

Vishay / Beyschlag

FUSE BOARD MNT 750MA 32VDC 0805

0

3-103-106

3-103-106

Schurter

MGA-A FUSE 1A SOLID STATE THIN F

7501500

0034.3124

0034.3124

Schurter

FUSE GLASS 5A 250VAC 5X20MM

21987

GMA-1-R

GMA-1-R

PowerStor (Eaton)

FUSE GLASS 1A 250VAC 5X20MM

7115

0312.187HXP

0312.187HXP

Wickmann / Littelfuse

FUSE GLASS 187MA 250VAC 3AB 3AG

57

SR-5-2.5A-AP

SR-5-2.5A-AP

PowerStor (Eaton)

FUSE BOARD MOUNT 2.5A 250VAC RAD

984

MDA-1/32

MDA-1/32

PowerStor (Eaton)

FUSE CERAMIC 32MA 250VAC 3AB 3AG

0

37305000430

37305000430

Wickmann / Littelfuse

FUSE BOARD MNT 500MA 250VAC RAD

192

027301.5V

027301.5V

Wickmann / Littelfuse

FUSE BOARD MOUNT 1.5A 125VAC/VDC

25

SF-1206SA700W-2

SF-1206SA700W-2

J.W. Miller / Bourns

FUSE 1206

3070

0034.6820

0034.6820

Schurter

FUSE BRD MNT 3.15A 250VAC 125VDC

600

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures

RFQ BOM Call Skype Email
Top